Issue Date: Page 1 of 1 Report Reference # E314798-A5-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No.
Issue Date: Page 1 of 3 Report Reference # E314798-A5-UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Issue Date: Page 2 of 3 Report Reference # E314798-A5-UL The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 60 degree C The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): output port (CN1, CN2, CN3) Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by U
Issue Date: Page 3 of 3 Report Reference # E314798-A5-UL Production-Line Testing Requirements Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information.
Issue Date: Page 1 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test 1 GENERAL Pass 1.5 Components Pass 1.5.1 General Pass 1.5.2 Result - Remark Verdict Comply with IEC 60950-1 or relevant component standard (see appended table 1.5.1) Pass Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard.
Issue Date: Page 2 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 1.5.9.2 Protection of VDRs N/A 1.5.9.3 Bridging of functional insulation by a VDR N/A 1.5.9.4 Bridging of basic insulation by a VDR N/A 1.5.9.5 Bridging of supplementary, double or reinforced insulation by a VDR N/A 1.6 Power interface 1.6.1 AC power distribution systems 1.6.2 Input current N/A 1.6.3 Voltage limit of hand-held equipment N/A 1.6.
Issue Date: Page 3 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test 1.7 Marking and instructions 1.7.1 Power rating and identification markings 1.7.1.1 Power rating mark N/A Multiple mains supply connections ...........: N/A Rated voltage(s) or voltage range(s) (V) ..: N/A Symbol for nature of supply, for d.c. only .: N/A Rated frequency or rated frequency range (Hz) ..........................................................: N/A Rated current (mA or A) .....
Issue Date: Page 4 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 1.7.5 Power outlets on the equipment ...............: N/A 1.7.6 Fuse identification (marking, special fusing characteristics, cross-reference) ..............: N/A 1.7.7 Wiring terminals N/A 1.7.7.1 Protective earthing and bonding terminals: N/A 1.7.7.2 Terminals for a.c. mains supply conductors N/A 1.7.7.3 Terminals for d.c. mains supply conductors N/A 1.7.
Issue Date: Page 5 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2 PROTECTION FROM HAZARDS 2.1 Protection from electric shock and energy hazards 2.1.1 Protection in operator access areas To be evaluated in the end product. N/A 2.1.1.1 Access to energized parts Class III unit intended to be powered by a SELV circuit in the end-product. N/A Pass N/A Test by inspection ....................................
Issue Date: Page 6 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 2.2 SELV circuits 2.2.1 General requirements 2.2.2 Voltages under normal conditions (V) ......: All accessible voltages are Verdict Pass Class III unit intended to be powered by a SELV circuit in the end-product. Pass Pass less than 42.4 Vp or 60 Vdc and are classified as SELV. 2.2.3 Voltages under fault conditions (V) ..........
Issue Date: Page 7 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.4 Limited current circuits N/A 2.4.1 General requirements N/A 2.4.2 Limit values N/A Frequency (Hz) ........................................: - Measured current (mA) ............................: - Measured voltage (V) ...............................: - Measured circuit capacitance (nF or uF) ..: - 2.4.
Issue Date: Page 8 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test 2.6 Provisions for earthing and bonding N/A 2.6.1 Protective earthing N/A 2.6.2 Functional earthing N/A 2.6.3 Protective earthing and protective bonding conductors N/A 2.6.3.1 General N/A 2.6.3.2 Size of protective earthing conductors N/A Rated current (A), cross-sectional area (mm²), AWG .............................................: 2.6.3.
Issue Date: Page 9 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.6.5.6 Corrosion resistance N/A 2.6.5.7 Screws for protective bonding N/A 2.6.5.8 Reliance on telecommunication network or cable distribution system N/A 2.7 Overcurrent and earth fault protection in primary circuits N/A 2.7.1 Basic requirements N/A Instructions when protection relies on building installation N/A 2.7.2 Faults not covered in 5.3.7 N/A 2.7.
Issue Date: Page 10 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test 2.9 Electrical insulation 2.9.1 Properties of insulating materials 2.9.2 Humidity conditioning Result - Remark Pass Natural rubber, materials containing asbestos and hygroscopic materials are not used as insulation. Grade of insulation 2.9.4 Separation from hazardous voltages Method(s) used ........................................: Pass N/A Relative humidity (%), temperature (°C) ...: 2.9.
Issue Date: Page 11 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 2.10 Clearances, creepage distances and distances through insulation Pass 2.10.1 General Pass Supplied by SELV, and no hazardous voltage generated within unit, only functional insulation required. Verdict For functional insulation, see 5.3.4. Pollution degree 2 applicable. 2.10.1.1 Frequency ................................................: N/A 2.10.1.2 Pollution degrees .....
Issue Date: Page 12 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 2.10.3.5 Clearances in circuits having starting pulses N/A 2.10.3.6 Transients from a.c. mains supply ............: Assume 1500 Vpk N/A 2.10.3.7 Transients from d.c. mains supply ............: N/A 2.10.3.8 Transients from telecommunication networks and cable distribution systems ..: N/A 2.10.3.
Issue Date: Page 13 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 2.10.5.11 Insulation in wound components N/A 2.10.5.12 Wire in wound components N/A Working voltage .......................................: N/A a) Basic insulation not under stress .........: N/A b) Basic, supplementary, reinforced insulation ..................................................: N/A c) Compliance with Annex U ....................
Issue Date: Page 14 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test 2.10.8.4 Abrasion resistance test N/A 2.10.9 Thermal cycling N/A 2.10.10 Test for Pollution Degree 1 environment and insulating compound N/A 2.10.11 Tests for semiconductor devices and cemented joints N/A 2.10.12 Enclosed and sealed parts N/A 3 WIRING, CONNECTIONS AND SUPPLY 3.1 General N/A 3.1.1 Current rating and overcurrent protection N/A 3.1.
Issue Date: Page 15 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test 3.2 Connection to mains supply 3.2.1 Means of connection 3.2.1.1 Connection to an a.c. mains supply N/A 3.2.1.2 Connection to a d.c. mains supply N/A 3.2.2 Multiple supply connections N/A 3.2.3 Permanently connected equipment N/A Number of conductors, diameter of cable and conduits (mm) ...................................
Issue Date: Page 16 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 3.3 Wiring terminals for connection of external conductors N/A 3.3.1 Wiring terminals N/A 3.3.2 Connection of non-detachable power supply cords N/A 3.3.3 Screw terminals N/A 3.3.4 Conductor sizes to be connected N/A Rated current (A), cord/cable type, crosssectional area (mm²) ................................: 3.3.
Issue Date: Page 17 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 3.5 Interconnection of equipment Pass 3.5.1 General requirements Pass 3.5.2 Types of interconnection circuits ..............: Interconnection circuits are Pass SELV CIRCUITS. 3.5.3 ELV circuits as interconnection circuits 3.5.4 Data ports for additional equipment 4 PHYSICAL REQUIREMENTS 4.1 Stability Angle of 10° Test force (N) ...................................
Issue Date: Page 18 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test 4.2 Mechanical strength 4.2.1 General Result - Remark Verdict N/A Unit for built-in. Suitable mechanical enclosure shall be provided in end-product. N/A Rack-mounted equipment N/A 4.2.2 Steady force test, 10 N N/A 4.2.3 Steady force test, 30 N N/A 4.2.4 Steady force test, 250 N N/A 4.2.5 Impact test N/A Fall test N/A Swing test N/A 4.2.6 Drop test; height (mm)....................
Issue Date: Page 19 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 4.3 Design and construction 4.3.1 Edges and corners 4.3.2 Handles and manual controls; force (N) ...: N/A 4.3.3 Adjustable controls N/A 4.3.4 Securing of parts N/A 4.3.5 Connection by plugs and sockets N/A 4.3.6 Direct plug-in equipment N/A Torque ......................................................: N/A Compliance with the relevant mains plug standard .....
Issue Date: Page 20 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test CRT markings ..........................................: Result - Remark Verdict - Effect of ultraviolet (UV) radiation on materials N/A Part, property, retention after test, flammability classification .........................: N/A 4.3.13.4 Human exposure to ultraviolet (UV) radiation ...................................................: N/A 4.3.13.
Issue Date: Page 21 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 4.5 Thermal requirements N/A 4.5.1 General N/A 4.5.2 Temperature tests N/A Normal load condition per Annex L ..........: . Verdict - 4.5.3 Temperature limits for materials N/A 4.5.4 Touch temperature limits N/A 4.5.5 Resistance to abnormal heat....................: N/A 4.6 Openings in enclosures N/A 4.6.
Issue Date: Page 22 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 4.7 Resistance to fire Pass 4.7.1 Reducing the risk of ignition and spread of flame Pass Method 1, selection and application of components wiring and materials Pass Method 2, application of all of simulated fault condition tests Verdict N/A 4.7.2 Conditions for a fire enclosure Unit intended for building-in. To be investigated in the end product. N/A 4.7.2.
Issue Date: Page 23 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 5.1 Touch current and protective conductor current 5.1.1 General 5.1.2 Configuration of equipment under test (EUT) N/A 5.1.2.1 Single connection to an a.c. mains supply N/A 5.1.2.2 Redundant multiple connections to an a.c. mains supply N/A 5.1.2.3 Simultaneous multiple connections to an a.c.
Issue Date: Page 24 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict telecommunication networks a) EUT with earthed telecommunication ports .........................................................: N/A b) EUT whose telecommunication ports have no reference to protective earth N/A 5.2 Electric strength N/A 5.2.1 General N/A 5.2.2 Test procedure N/A 5.3 Abnormal operating and fault conditions 5.3.
Issue Date: Page 25 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 6 CONNECTION TO TELECOMMUNICATION NETWORKS N/A 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment N/A 6.1.1 Protection from hazardous voltages N/A 6.1.2 Separation of the telecommunication network from earth N/A 6.1.2.1 Requirements N/A Supply voltage (V) .................
Issue Date: Page 26 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N/A 7.1 General N/A 7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment N/A 7.3 Protection of equipment users from overvoltages on the cable distribution system N/A 7.
Issue Date: Page 27 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N/A A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2) N/A A.1.1 Samples ...................................................: - Wall thickness (mm) .................................: - A.1.
Issue Date: Page 28 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Sample 1 burning time (s) ........................: - Sample 2 burning time (s) ........................: - Sample 3 burning time (s) ........................: - A.3 Hot flaming oil test (see 4.6.2) N/A A.3.1 Mounting of samples N/A A.3.2 Test procedure N/A A.3.
Issue Date: Page 29 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see 4.7.2.2 and 5.3.2) N/A B.1 General requirements N/A Position ....................................................: - Manufacturer ............................................: - Type .........................................................: - Rated values ............................................: - B.
Issue Date: Page 30 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test C ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) Result - Remark Verdict N/A Position ....................................................: - Manufacturer ............................................: - Type .........................................................: - Rated values ............................................: - Method of protection ................................: - C.
Issue Date: Page 31 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES N/A G.1 Clearances N/A G.1.1 General N/A G.1.2 Summary of the procedure for determining minimum clearances N/A G.2 Determination of mains transient voltage (V) N/A G.2.1 AC mains supply ......................................: N/A G.2.2 Earthed d.c. mains supply ........................: N/A G.2.3 Unearthed d.c.
Issue Date: Page 32 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8) N/A K.1 Making and breaking capacity N/A K.2 Thermostat reliability; operating voltage (V) ............................................................: N/A K.3 Thermostat endurance test; operating voltage (V) ................................................: N/A K.
Issue Date: Page 33 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N/A M.1 Introduction N/A M.2 Method A N/A M.3 Method B N/A M.3.1 Ringing signal N/A M.3.1.1 Frequency (Hz) ........................................: - M.3.1.2 Voltage (V) ...............................................: - M.3.1.3 Cadence; time (s), voltage (V) ..................: - M.3.1.
Issue Date: Page 34 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N/A S.1 Test equipment N/A S.2 Test procedure N/A S.3 Examples of waveforms during impulse testing N/A T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2) N/A .................................................................
Issue Date: Page 35 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark Verdict Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N/A Y.1 Test apparatus .........................................: N/A Y.2 Mounting of test samples .........................: N/A Y.3 Carbon-arc light-exposure apparatus .......: N/A Y.4 Xenon-arc light-exposure apparatus ........: N/A Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.
Issue Date: Page 36 of 36 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test EE ANNEX EE, HOUSEHOLD AND HOME/OFFICE DOCUMENT/MEDIA SHREDDERS N/A EE.1 General N/A EE.2 Markings and instructions N/A Use of markings or symbols .....................: N/A Information of user instructions, maintenance and/or servicing instructions: N/A EE.3 Inadvertent reactivation test .....................: N/A EE.
Issue Date: Page 1 of 1 Report Reference # E314798-A5-UL IEC 60950-1 Clause Requirement + Test Result - Remark 1.5.1 Object/part or Description TABLE: list of critical components Manufacturer/ type/model trademark 01. PWB -- -- 02. Label -- -- 02a. Permanency of Marking (Alternate) -- -- 03. Connectors and Receptacles (Sec.) (ELV, SELV) 03a. Connectors and Receptacles (Sec.) (ELV, SELV) (Alternate) 04. Polyswitch (F1, F3) for PUSB port (CN1, CN2, CN3); used 05.
Issue Date: Page 1 of 24 Report Reference # Enclosures Enclosures Type Supplement Id Photographs 3-01 Front View(PUB1200XL) Photographs 3-02 Rear View(PUB1200XL) Photographs 3-03 Side View(PUB1200XL) Photographs 3-04 Front View(PUB1200X) Photographs 3-05 Rear View(PUB1200X) Photographs 3-06 Side View(PUB1200X) Photographs 3-07 Front View(PUB0300XL) Photographs 3-08 Rear View(PUB0300XL) Photographs 3-09 Side View(PUB0300XL) Diagrams 4-01 Circuit Diagram (PUB1200XL, PUB1200X
Issue Date: Page 2 of 24 Report Reference # Enclosures Photographs ID 3-01 E314798-A5-UL
Issue Date: Page 3 of 24 Report Reference # Enclosures Photographs ID 3-02 E314798-A5-UL
Issue Date: Page 4 of 24 Report Reference # Enclosures Photographs ID 3-03 E314798-A5-UL
Issue Date: Page 5 of 24 Report Reference # Enclosures Photographs ID 3-04 E314798-A5-UL
Issue Date: Page 6 of 24 Report Reference # Enclosures Photographs ID 3-05 E314798-A5-UL
Issue Date: Page 7 of 24 Report Reference # Enclosures Photographs ID 3-06 E314798-A5-UL
Issue Date: Page 8 of 24 Report Reference # Enclosures Photographs ID 3-07 E314798-A5-UL
Issue Date: Page 9 of 24 Report Reference # Enclosures Photographs ID 3-08 E314798-A5-UL
Issue Date: Page 10 of 24 Report Reference # Enclosures Photographs ID 3-09 E314798-A5-UL
Issue Date: Page 11 of 24 Report Reference # Enclosures Diagrams ID 4-01 E314798-A5-UL
Issue Date: Page 12 of 24 Report Reference # Enclosures Diagrams ID 4-01 E314798-A5-UL
Issue Date: Page 13 of 24 Report Reference # Enclosures Diagrams ID 4-01 E314798-A5-UL
Issue Date: Page 14 of 24 Report Reference # Enclosures Diagrams ID 4-01 E314798-A5-UL
Issue Date: Page 15 of 24 Report Reference # Enclosures Diagrams ID 4-01 E314798-A5-UL
Issue Date: Page 16 of 24 Report Reference # Enclosures Diagrams ID 4-01 E314798-A5-UL
Issue Date: Page 17 of 24 Report Reference # Enclosures Diagrams ID 4-01 E314798-A5-UL
Issue Date: Page 18 of 24 Report Reference # Enclosures Diagrams ID 4-02 E314798-A5-UL
Issue Date: Page 19 of 24 Report Reference # Enclosures Diagrams ID 4-02 E314798-A5-UL
Issue Date: Page 20 of 24 Report Reference # Enclosures Diagrams ID 4-02 E314798-A5-UL
Issue Date: Page 21 of 24 Report Reference # Enclosures Diagrams ID 4-02 E314798-A5-UL
Issue Date: Page 22 of 24 Report Reference # Enclosures Diagrams ID 4-02 E314798-A5-UL
Issue Date: Page 23 of 24 Report Reference # Enclosures Diagrams ID 4-02 E314798-A5-UL
Issue Date: Page 24 of 24 Report Reference # Enclosures Diagrams ID 4-02 E314798-A5-UL
TABLE 2.5: Limited power sources This document must only be imported in the table listed above. It will not work in any other table or row. � Enter required data and SAVE IT AS A DOCUMENT (extension.doc). � DO NOT change the NUMBER OF COLUMNS or modify the first row �To delete a row or rows, highlight the row or rows to be deleted and choose 'Delete Rows' from the 'Table' menu. �To add a new row, place the cursor in an existing row and select 'Insert Rows' from the 'Table' menu. Meas. Limit Meas.
pin2-8 / 0V PUSB port (CN3) 3.1 8 12.71 100 PUSB port (CN3) 4.5 Pin6 / 12.08V 8 41.08 100 PUSB port (CN3) 4.5 8 41.08 100 For PUB0300XL -- -- -- -- Normal condition -- -- -- -- PUSB port (CN1) 0 Pin2-5 / 0V 8 0 100 PUSB port (CN1) 0 Pin2-8 / 0V 8 0 PUSB port (CN1) 4.6 Pin6 / 12.05V 8 41.63 100 PUSB port (CN1) 4.6 Pin7 / 12.05V 8 41.63 100 PUSB port (CN1) 3.2A Pin1 / 5.01V 8 12.
Pin1 / 5.