Safety Information

Issue Date:
Page 1 of 3
Report Reference #
E314798-A5-UL
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A.
Authorization - The Authorization page may include additional Factory Identification Code markings.
B.
Generic Inspection Instructions -
i.
Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii.
Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii.
Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
DC power supply, electric components mounted on PWB, with 24V & 12V Powered USB connectors,
providing the necessary power as well as the communication signals. PCI Express allows the board to be
installed in any slim size PC-based system with low profile bracket structure
Model Differences
-Model PUB1200X, PUB1200XL are identical to each other except for length of bezel.
-Model PUB0300XL and PUB1200X are identical to each other except for output CN1: 12V-PUSB for
PUB0300XL and 24V-PUSBfor PUB1200X.
Technical Considerations
Equipment mobility : for building-in
Connection to the mains : No direct connection
Operating condition : continuous
Access location : for building-in
Over voltage category (OVC) : OVC I
Mains supply tolerance (%) or absolute mains supply values : No direct connection
Tested for IT power systems : N/A
IT testing, phase-phase voltage (V) : N/A
Class of equipment : Class III (supplied by SELV)
Considered current rating of protective device as part of the building installation (A) : N/A
Pollution degree (PD) : PD 2
IP protection class : IP X0
Altitude of operation (m) : Up to 2000 m
Altitude of test laboratory (m) : Up to 2000 m
Mass of equipment (kg) : PUB0300XL:0.07Kg , PUB1200X:0.095Kg, PUB1200XL:0.085Kg