Instructions / Assembly
May 16 Made in China 11 / 13
OPERATION
LEAK TEST
1. Make sure the control knob is in the “OFF” position.
2. Make sure the gas cylinder is correctly and securely connected to the pressure regulator, without over tightening.
3. Turn on the gas cylinder valve. Apply 50% soap and 50% water solution to the gas hose and connections between the
control knob and gas cylinder.
4. If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the leaking connection,
re-connect it and try again. If the leak persists, consult Customer Service Center for assistance (1-866-578-0101).
5. If the connection does not leak, continue to the next step.
LIGHTING THE BURNERS
1. Make sure control valve is OFF.
2. Turn on gas tank valve.
3. Press in and turn control valve knob counterclockwise to high to light. See the
figure to the right.
4. If burner is lit, continue pressing in the control valve knob for a minute to heat
the thermocouple.
5. When control valve knob is released, the burner should be lit. If not, turn
control valve knob clockwise to OFF. Wait for 5 minutes then start with step 3
above.
6. Press in and turn control valve knob to desired heat output, HIGH ~ LOW.
NOTE: While in use, the burner flame should be mainly blue in appearance with a small amount of yellow. The flame can be
identified by the following figure.
Warning: Lighting the Fire Pit improperly could lead to an unsafe condition.
6. Press in and turn the control valve knob clockwise to OFF to shut down fireplace. Close the gas cylinder valve when the
fireplace is not in use.
(CAUTION: Do not kink flexible gas hose. If it is kinked, a gas leak could occur.)
!!!WARNING!!!
Do not use an open flame to check for leaks.
Do not smoke during testing.
Do not test indoors.
A leak check must be
p
erformed whenever the
g
as c
y
linder is re
p
laced.
Incorrect Flame
YELLOW TIPS
BLUE
HIGH
LOW
Correct Flame
BLUE
LOW
OFF
HIGH
MAX
BAS
ARRET
LOW