Instructions / Assembly
May 16 Made in China 12 / 13
STORAGE AND MAINTENANCE
To obtain the best performance from your fireplace, you must perform the following storage and maintenance activities on a
regular basis:
Allow at least 35 minutes for the fireplace to cool down after use, before disconnecting and removing the gas cylinder.
Store the gas cylinder in a dry, well-ventilated and sheltered area protected from inclement weather and dust, out of the
reach of children, and not in a building, garage or any other closed area.
The fireplace may be stored indoors only if the cylinder is disconnected and removed.
Keep the fireplace area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
Installation and repair should be done by a qualified service person. The fireplace should be inspected before use
and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is
imperative that the control compartment, burner, and circulating air passageways of the fireplace be kept clean.
If you disassemble the burner when cleaning the fireplace, please reassemble it
according to the picture on the right to make sure the burner induction tunnel is on and
exactly cover the orifice base.
It is imperative that the control compartment, burner,
and circulating air passageways of the fireplace be kept clean.
It is recommended not
to disassemble the burner.
Permanent installation and repair should be done by a qualified service person. The
fireplace should be inspected annually by a qualified service person.
TROUBLE SHOOTING
PROBLEM OBSERVED POSSIBLE CAUSE CORRECTIVE MEASURES
Gas odor Gas leak See “If you smell gas:” on front cover of
manual
Check all gas connections
Delayed ignition Low gas pressure
Clogged or dirty burner ports
Blocked orifice
Spent battery
Check gas supply pressure
Clean burner ports-see manual section
Check orifice opening
Change new battery
Incorrect burner flame Incorrect gas supply or pressure
Blocked orifice
Clogged or dirty burner ports
Check gas supply pressure
Check and clean orifice opening
Clean burner ports