Installation Guide

Country of Origin: China 17 of 19
OPERATION:
LEAK TEST
!!!WARNING!!!
Do not use an open flame to check for leaks.
 
Do not smoke during testing.
 
Do not test indoors.
 
A leak check must be performed whenever the gas cylinder is replaced.
1. Make sure the control knob is in the “OFF” position.
2. Make sure the gas cylinder is correctly and securely connected to the pressure regulator, without over
tightening.
3. Turn on the gas cylinder valve. Apply 50% soap and 50% water solution to the gas hose and
connections between the control knob and gas cylinder.
4. If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the
leaking connection, re-connect it and try again. If the leak persists, consult Customer Service Center for
assistance (1(866) 578-6569).
5. If the connection does not leak, continue to the next step.
LIGHTING THE BURNERS
1. Push in and turn control knob to LOW.
2. If the burner is not lit, turn the knob back to "OFF" . Wait 5 minutes
and repeat step 1.
3. If burner is lit,Continue to depress control knob for 1-2 minutes until the
thermocouple is hot.
4. Release control knob and the burner should stay lit.
5. Turn control knob to desired heat setting,LOW-HIGH.
6. Turn control knob to OFF to shutdown. Turn off gas supply at
cylinder.Allow a 5-minutes complete shut off period before relighting the
appliance.
Fig 8
OFF
HIGH
MAX
BAS
ARRET
LOW
Fig 7
Fig.7