LEAK TEST
!!!WARNING!!!
Do not use an open flame to check for leaks.
Do not sm
oke during testing.
Do not test indoo
rs.
A
leak check must be performed whenever the gas cylinder is replaced.
1- Make sure the control knob is in the “OFF” position.
2- Make sure the gas cylinder is correctly and securely connected to the pressure regulator, without ove
r
tigh
tening
.
3-
Turn on the gas cylinder valve. Apply 50% soap and 50% water solution to the gas hose and connections
between the control knob and gas cylinder.
4-
If something is leaking, you will see bubbles form. In case of leaks, turn off the gas supply, undo the leaking
connection, re-connect it and try again. If the leak persists, consult Customer Service Center for assistan
ce
(
1(866) 578-6569).
5- If the connection does not leak, continue to the next step
.