Installation Guide
8/9
Made in China
Keep the fireplace area clear and free from combustible materials, gasoline and other flammable vapors and
liquids.
Installation and repair should be done by a qualified service person. The fireplace should be inspected
before use and at least annually by a qualified service person. More frequent cleaning may be required as
necessary. It is imperative that the control compartment, burner, and circulating
air passageways of the fireplace be kept clean.
If you disassemble the burner when cleaning the fireplace, please reassemble it
according to the picture on the right to make sure the burner induction tunnel is on and
exactly cover the orifice base. It is imperative that the control compartment, burner, and
circulating air passageways of the fireplace be kept clean. It is recommended not to
disassemble the burner.
Permanent installation and repair should be done by a qualified service person.
The fireplace should be inspected annually by a qualified service person.
TROUBLE SHOOTING:
P
ROBLEM OBSERVED POSSIBLE CAUSE CORRECTIVE MEASURES
Gas odor Gas leak See “If you smell gas:” on front cover of manual
Check all gas connections
Delayed ignition Low gas pressure
Clogged or dirty burner ports
Blocked orifice
Spent battery
Check gas supply pressure
Clean burner ports-see manual section
Check orifice opening
Change new battery
Incorrect burner flame Incorrect gas supply or pressure
Blocked orifice
Clogged or dirty burner ports
Check gas supply pressure
Check and clean orifice opening