Quest 110 Dual Installation, Operation and Maintenance Instructions
6
www.QuestProtect.com
sales@QuestProtect.com
4.2B Duct Outlet (g. 2)
Dehumidicationperformancecanbemodiedbyaddinganoutletducttocirculateair.
4.2C Remote Area, w/Outlets Ducted (g. 3)
AmoresimpliedremoteinstallationmethodthanaboveusesductingbetweentheQuest110Dual
dischargeandthehumidroom;theQuest110Dualinletdrawsairfromtheroominwhichit’slocated.This
workswellifthereisanadequateairowpathbetweenthetworooms;e.g.highdoorundercutorwallgrill.
This eliminates the need to remote mount the humidity control.
4.3 Electrical Requirements
The Quest 110 Dual plugs into a common grounded outlet on a 110-120 VAC 15-Amp circuit. While
operating,itdrawslessthan7.2amps@80°F,60%RHandlessthan6.8amps@75°F,50%RH.Useof
a ground fault circuit interrupter (GFCI) protected circuit is recommended. The unit should not be used in
areaspronetoooding.
Input of
Humid Air
Output of
Dehumidified Air
Front View
Figure 2: Installation in humid
area with outlet ducting.
CONDITIONED SPACE
Input of
Humid Air
Output of
Dehumidified Air
Figure 3: Installation in a remote
area with ducted outlets.