Installation Instructions Sunnex HM Exam Light Models: HM1006-37W, HM28002W, HM1000-37W, HM2017-44 1.1 Applications This HM LIGHT is intended to be used as a medical examination lamp in consulting rooms and health care centers.
1.2 Cleaning and Disinfection The lamp fixture can be cleaned as needed with a damp cloth and a mild detergent. For disinfection use a soft cloth with a disinfectant solution such as isopropyl alcohol. NOTE! Do not introduce any fluids to the inside of the lamp head as this could cause a fire hazard. The glass lens can be cleaned with a damp cloth and a mild detergent and inside part of the lens can be easily cleaned with Q-tips. Technical Data 2.1 Manufacturer Sales office Sunnex, Inc.
2.3 Transportation and Storage This light is packaged in card board and should be transported protected from moisture. The light should be stored in a dry environment and room temperature. Transportation and storage temperature: -5°F / -20°C to 140°F / 60°C Humidity < 95% 2.4 Bulb replacement 1 2 3 4 5 6 1. Lamp front, part#: 18018 2. Bulb support, part#: 18291 3. Color filter, part#: 18676 4. MR 16 bulb, part#: 18562 5. Lamp back, part# 18016 6. Screws, part#: 4475057 1.
2.1 HM LIGHT Mobile (HM1006-37W) 1. Place the pole (2) in the center housing (4) 2. Press down until you feel resistance. Assemble the clamp plate (5) using the provided screw (7) and washer (6). Do not tighten the screw. The teeth on the plate should face inwards. 3. Insert each of the 5 legs into the center housing, and place the 2 lockable casters on opposite sides. 4. Tighten the screw (7). Secure the legs in the housing by lining up the teeth on the clamp plate (5) with the holes in the legs. 2.
HM WALL BRACKET HOLE PATTERN 2.3 HM LIGHT Wall - Gooseneck Arm (HM1000-37W) 1. Mount the light using four screws. There are four holes on the universal mount. 2. Be sure transformer plug is not plugged into power source at this time. 3. After universal mount is secured, plug in the plug-in transformer to use the light. Universal Joint HM Light Wall – Gooseneck Arm 2.4 HM LIGHT Ceiling (HM2017-44) 1. Securely fasten lamp down tube from ceiling.
2. Be sure transformer plug is not plugged into power source at this time. 3. After down tube support is secured plug electrical connectors at the end of the down tube support and lamp arm together. HM CEILING DOWN TUBE HOLE PATTERN 2.6 Symbols CE-Mark AC powered: This product must be sorted as Waste from Electrical and Electronic Equipment (WEEE): 3. Sunnex Limited Warranty 3.1 Limited Warranty.
warranty period, Sunnex, at its option, will repair or replace the Product, at no charge or refund the then-current value of the Product. 3.2 Disclaimers and Limitations. This Limited Warranty shall be the sole remedy of Customer and the sole liability of Sunnex to Customer.
packaging of any Product shipped to Sunnex. (c) Within ten (10) days of receipt of the RMA number, Customer must ship the Product to Sunnex at Customer’s expense (insuring the Product is recommended) in either its original packaging or packaging affording an equal degree of protection, to Sunnex Inc. 3 Huron Drive, Natick MA 01760, with a statement describing the problem in reasonable specificity. Proof of purchase must be included to obtain warranty service.
Sunnex Customer Service Sunnex Inc, USA Sunnex Equipment AB Sweden Warranty + 1 508 651 0009 + 46 565 177 00 + 1 508 651 0009 Guidance and manufacturer’s declaration — electromagnetic emissions The HM LIGHT is intended for use in the electromagnetic environment specified below. The customer or the user of the HM LIGHT should assure that it is used in such an environment.
for 5 cycles for 5 cycles 70 % UT (30 % dip In UT) for 25 cycles 70 % UT (30 % dip in UT) for 25 cycles <5% UT (>95 % dip In UT) for 5 s <5% UT (>95 % dip in UT) for 5 s Power frequency (50/60 Hz) magnetic field IEC 6 1000-4-8 3 A/m 0,3 A/m HM LIGHT Image Intensifier be powered from an uninterruptible power supply or a battery.
Portable and mobile RF communications equipment should be used no closer to any part of the HM LIGHT, including cables, than the recommended applicable to the frequency of the transmitter.
equipment.