- SUNPENTOWN Int'l Inc. Instruction Manual PORTABLE Air Conditioner WA-1010E, WA-1010H, WA-1010M, WA-1230E, WA-1230H

`
Model Number
WA-1010E
WA-1010M
WA-1010H
Cooling Capacity 10,000BTU/hr 10,000BTU/hr
Heating Capacity (1)(2) N/A
10,000BTU/hr
Power Consumption 660W / 6.3A
660W / 6.3A
Humidity Removal Capacity 50 pts./day
50 pts./day
Recommended Room Size* 300 sq. ft.
300 sq. ft.
Power Supply 120V / 60H / 1 Phase 120V / 60H / 1 Phase
Compressor Rotary
Rotary
Refrigerant R-22
R-22
Fan Speed 2 2
Timer WA-1010E: 1-12hours 1-12 hours
WA-1010M: 1-8hours
Thermostat 64°F - 90°F 64° F - 90°F
Net Weight
Dimensions 17"W x 17"D x 30"H 17"W x 17"D x 30"H
Working Temperature
Cooling: 64°F to 110°F
Cooling: 64°F to 110°F
Heating: 41°F to 81°F
REMARKS:
1. The data may vary, please refer to the rating label on the back on the back of the unit.
2. The above conditions are measured at:
Cooling - Indoor: RT 81°F, RH 60%
Heating - Indoor: RT 68°F, RH 60%
* Uninsulated rooms such as sunrooms, garages, or attics should be less than 300 sq. ft.
S
p
ecifications
Draina
g
e
During the process of cooling or heating, some water will be extracted from the air into the unit. Most o
f
this water is used to cool the unit and make it run more efficiently. This is a feature not found in mos
t
Portable Air Conditioners. If the unit is operated in VERY HUMID air, water will collect in the container
inside the unit. If the water container is full, the compressor and fan will stop. The POWER indicator will
b
link to inform you to empty the
internal container. To make the cooling function work again, please
empty the water by one of the following methods:
2
1
2
By the Draining into a Container
Use a Shallow Container or Dish
1. Turn off the unit.
2. Position a flat container or dish under the drain hole.
Do not allow the water to drip continuously into the container, as i
t
might easily overflow.
3. Remove the drain knob & rubber plug from the drain hole. The
condensed water will drain out automatically.
4. When the container is almost full, replace the rubber plug into
the drain hole to stop the water. Empty the container.
5. Repeat steps 2, 3 & 4 until all the condensed water is emptied.
6. Once all the condensed water has been removed, replace the
rubber plug into the drain hole firmly. The Full Water indicator
should be off now.
7. Replace the drain knob.
* Do not allow the water to drip continuously into the tray, as it
may easily overflow.
By Water Tube (Continuous Drainage)
1. Remove the drain knob and rubber plug and keep them for
future use.
2. Use Teflon tape to cover threading on spout, making a flat
surface for the hose. This will prevent leakage.
3. Connect a suitable water tube (of 3/4" internal diameter -
supplied) to the water hole. The condensed water will drain out
automatically.
4. If you want to extend the water tube you can connect it with
another tube (outside diameter ¾”).
Special Caution for Heating Function!
1. Install the exhaust pipe securely in order to exhaust
the cool air to the outside (please see page 6).
2. You can use the continuous drainage option as described above.
3. The warmer the outside air the more heat will be pumped into
the room. Working range for heat pump function is 41°F to 81°F.
When used in room temperatures outside this range the unit may
not function properly.
4. While using the heating function during low temperatures,
sometimes the heating will stop for a while in order to melt the
internal frost. When this occurs, just wait for heating to resume.
This is normal for compressor operated devices.
Rubber Plug
Drain Knob
W
ater Hole
Rubber Plug
Drain Knob
Drain Pipe
riginal W
ater T
ube
Extended W
ater T
ube
(OD:
3/4")
O
z
z
63 lbs
66 lbs