Data Sheet

SUNPOWER TECHNOLOGY CORP.
16F.-1, No.150, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.).
TEL: 886-2-8226-3100 FAX: 886-2-8226-3111
http://www.sunpower.com.tw
E-mail: sunpower@sunpower.com.tw
SPE-150-xx Series
Copy Right Sunpower Technology Corp. 2009, All Rights Reserved. SPE-150-xx Rev 1.4
Specifications subject to change without notice. RS-140018 FEB-20-2020
QR0405-1 Rev,:1.0
Features:
Universal AC input with active PFC circuit, P.F.>0.95
1U low profile 30mm
Altitude during operation up to 16404ft ( 5000m )
Power ON with LED indicator
Built in EMI filter, low ripple noise
Over voltageover load short circuit protection
Over temperature protection
Output voltage ± 10% adjustment
Remote control ON/OFF
100% full load burn-in test
UL, cUL, TUV, CB, CE approved
3 years warranty
Specification:
INPUT
Voltage
Frequency
Current
Inrush Current(TYP.)
Leakage Current
Power Factor
OUTPUT
MODEL No.
SPE-150-05
SPE-150-12
SPE-150-24
SPE-150-48
Voltage
5V
12V
24V
48V
Min Load
0A
0A
0A
0A
Max Load
30A
12.5A
6.3A
3.2A
Output Tolerance
±2%
±1%
±1%
±1%
Ripple Noise MAX.
100mV
100mV
150mV
200mV
Efficiency (TYP.)
86%
88%
89%
90%
Output MAX.
150W
150W
151W
154W
PROTECTION
Over Voltage
5.8V~7.0V
13.8V~16.8V
27.6V~33.6V
55.2V~67.2V
Over Load Short Circuit
Over Temperature
ELEC. CHAR.
Rise time
Hold up time
Setup time
Remote Control
ENVIRONMENT
Temperature
Humidity
SAFETY
Withstand voltage
Isolation resistance
Safety standard
EMC
EMI
EMS
OTHERS
Cooling
M.T.B.F.
Dimension
Packing
NOTE
All measurements which not mentioned are based on 230VAC input, output Max at ambient 25 / 70%RH
Output tolerance included set up voltage, line regulation and load regulation.
Ripple & noise are measured at 100254VAC input with 1050 condition and 20MHz of bandwidth by using a 10〞〜15twisted pair-wire terminated
with a 0.1uF & a 47uF parallel capacitor.
The operating temperature shall follow the de-rating curve in spec
The output load may be requested for decreasing as de-rating curve in spec when low input voltage is under 100VAC.
The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives.
The ambient temperature should be de-rating by 5/1000m, when operating altitude higher than 2000m (6500 ft)
150W, Single Output
188 x 99 x 30 mm
7.4 x 3.9 x 1.18 inch
Active P.F.C Function
CB

Summary of content (3 pages)