Data Sheet
SUNPOWER TECHNOLOGY CORP.
16F.-1, No.150, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.).
TEL: 886-2-8226-3100 FAX: 886-2-8226-3111
http://www.sunpower.com.tw
E-mail: sunpower@sunpower.com.tw
SPE-150-xx Series
Copy Right Sunpower Technology Corp. 2009, All Rights Reserved. SPE-150-xx Rev 1.4
Specifications subject to change without notice. RS-140018 FEB-20-2020
QR0405-1 Rev,:1.0
Features:
* Universal AC input with active PFC circuit, P.F.>0.95
* 1U low profile 30mm
* Altitude during operation up to 16404ft ( 5000m )
* Power ON with LED indicator
* Built in EMI filter, low ripple noise
* Over voltage、over load & short circuit protection
* Over temperature protection
* Output voltage ± 10% adjustment
* Remote control ON/OFF
* 100% full load burn-in test
* UL, cUL, TUV, CB, CE approved
* 3 years warranty
Specification:
INPUT
Voltage
85V ~ 264VAC universal full range or 120V ~ 375VDC.
Frequency
47 ---- 63 Hz
Current
<2.2A @100V AC input, full load condition
Inrush Current(TYP.)
45A@230V AC input. Cold start at 25℃ ambient
Leakage Current
<1.5mA@264V AC input
Power Factor
PF > 0.95
OUTPUT
MODEL No.
SPE-150-05
SPE-150-12
SPE-150-24
SPE-150-48
Voltage
5V
12V
24V
48V
Min Load
0A
0A
0A
0A
Max Load
30A
12.5A
6.3A
3.2A
Output Tolerance
±2%
±1%
±1%
±1%
Ripple Noise MAX.
100mV
100mV
150mV
200mV
Efficiency (TYP.)
86%
88%
89%
90%
Output MAX.
150W
150W
151W
154W
PROTECTION
Over Voltage
5.8V~7.0V
13.8V~16.8V
27.6V~33.6V
55.2V~67.2V
Shutdown and latch off, recover after re-start up.
Over Load & Short Circuit
When power supply over 105%~ 150% max load or short circuit acted, power supply will go into hiccup mode
and recover automatically after the fault is removed.
Over Temperature
Shutdown output voltage, recovers automatically after fault condition has been removed.
ELEC. CHAR.
Rise time
<20mS
Hold up time
>16mS@230V, full load condition
Setup time
<2.5S@100 ~ 240V AC
Remote Control
RC+/RC-: 0~0.8V= Power On; 4~10V= Power Off.
ENVIRONMENT
Temperature
Operating: -30 ~ +70℃ ; De-rating: 50 ~ 70℃: 2.5%/℃ ; Storage: -40 ~ +85℃
Humidity
Operating: 20% ~ 90% RH (non condensing) ; Storage: 10% ~ 95% RH (non condensing)
SAFETY
Withstand voltage
I/P-O/P:3KVAC, I/P-FG:1.8KVAC, O/P-FG:0.5KVAC, 1minute
Isolation resistance
I/P-O/P, I/P-FG, O/P-FG >100MΩ/500VDC at 25℃/ 70% RH
Safety standard
UL 60950-1 2
nd
,CAN/CSA C22.2 No. 60950-1- 07 2
nd
,UL 62368-1 2
nd
(edition dated 2014-12-01) ,
IEC60950-1:2005+A1+A2, IEC 62368-1:2014 (2
nd
.Edition),TUV EN 62368-1:2014 approved
EMC
EMI
EN 55032 CLASS B, FCC 47 CFR PART 15 CLASS B
Compliance to EN61000-3-2 CLASS D, EN61000-3-3
EMS
EN 55024:EN 61000-4-2,3,4,5,6,8,11
OTHERS
Cooling
Natural cooling
M.T.B.F.
162.8 K hours
Dimension
188 x 99 x 30 mm (L*W*H)
Packing
N.W.:0.56Kg / 1pc; 24pcs / 0.96 CUFT / 1 CTN
NOTE
All measurements which not mentioned are based on 230VAC input, output Max at ambient 25℃ / 70%RH
Output tolerance included set up voltage, line regulation and load regulation.
Ripple & noise are measured at 100〜254VAC input with 10〜50℃ condition and 20MHz of bandwidth by using a 10〞〜15〞twisted pair-wire terminated
with a 0.1uF & a 47uF parallel capacitor.
The operating temperature shall follow the de-rating curve in spec
The output load may be requested for decreasing as de-rating curve in spec when low input voltage is under 100VAC.
The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives.
The ambient temperature should be de-rating by 5℃/1000m, when operating altitude higher than 2000m (6500 ft)
150W, Single Output
188 x 99 x 30 mm
7.4 x 3.9 x 1.18 inch
Active P.F.C Function
CB