Features:
Green mode design, no load < 0.5W
High efficiency and high reliability
Built in EMI filter, low ripple noise
Over voltage protectionShutdown and latch off
Over load short circuit protectionHiccup mode
Output voltage ±10% adjustment
100% full load burn-in test
-20~70 Operating temperature
UL, cUL, TUV, CB, CE approved
3 years warranty
Specification:
INPUT
2BVoltage
88V ~ 264VAC universal full range or 125V ~ 375VDC.
Frequency
47 ----- 63 Hz
Current
<1.0A@100V AC input, full load condition
Inrush Current (TYP.)
30A@115V , 50A@230V AC input, Cold start at 25 ambient
Leakage Current
<1.0mA@264V AC input
OUTPUT
MODEL No.
SPS-035-05
SPS-035-7.5
SPS-035-12
SPS-035-15
SPS-035-24
SPS-035-48
Voltage
5V
7.5V
12V
15V
24V
48V
Min Load
0A
0A
0A
0A
0A
0A
Max Load
7A
4.7A
3A
2.4A
1.5A
0.8A
Output Tolerance
± 2%
± 1%
± 1%
± 1%
± 1%
± 1%
Ripple Noise MAX.
70mV
80mV
120mV
150mV
150mV
200mV
Efficiency (TYP.)
79%
80%
82%
84%
85%
86%
Output MAX.
35W
35W
36W
36W
36W
38W
PROTECTION
Over Voltage
5.8~7.0V
8.6~10.5V
13.8~16.8V
17.3~21.0V
27.6~33.6V
55.2~67.2V
Shutdown and latch off, recover after re-start up.
Over Load Short Circuit
When power supply over 105%~ 150% max load or short circuit acted, power supply will go into hiccup mode
and recover automatically after the fault is removed.
ELEC. CHAR.
Rise time
<20mS
Hold up time
>40mS@230V, full load condition
Setup time
<1 Sec@100 240V AC
Green mode function
Power consumption at no load < 0.5W
ENVIRONMENT
Temperature
Operating: -20 ~ +70 ; De-rating: 50 ~ 70: 2.5%/ ; Storage: -40 ~ +85
Humidity
Operating: 20% ~ 90% RH (non condensing) ; Storage: 10% ~ 95% RH (non condensing)
Altitude
6562 ft ( 2000 m) operating
SAFETY
Withstand voltage
I/P-O/P:3KVAC, I/P-FG:1.8KVAC, O/P-FG:0.5KVAC, 1minute
Isolation resistance
I/P-O/P, I/P-FG, O/P-FG 100MΩ/500VDC at 25/ 70% RH
Safety standard
UL 62368-1 2
nd
Edition, 2014-12-01, CAN/CSA C22.2 No. 62368-1-14, 2
nd
Edition, 2014-12, TUV EN 62368-1:2014+A11,
IEC 62368-1:2014 approved
EMC
EMI
EN 55032 CLASS B, FCC CFR 47 PART 15 CLASS B
Compliance to EN61000-3-2 CLASS A, EN61000-3-3
EMS
EN 55024EN 61000-4-2,3,4,5,6,8,11
OTHERS
Cooling
Natural cooling.
M.T.B.F.
398 K hours
Terminal pitch
5P / 9.5mm with plastic cover, 90 deg terminal optional (with MOQ)
Packing
N.W.: 0.34Kg / 1pc; 46pcs/ 1.22 CUFT / 1 CTN
NOTE
All measurements which not mentioned are based on 230VAC input, output Max at ambient 25 / 70%RH
Output tolerance included set up voltage, line regulation and load regulation.
Ripple & noise are measured at 100254VAC input with 1050 condition and 20MHz of bandwidth by using a 10〞〜15twisted pair-wire terminated
with a 0.1uF & a 47uF parallel capacitor.
The operating temperature shall follow the de-rating curve in spec
The output load may be requested for decreasing as de-rating curve in spec when low input voltage is under 100VAC.
The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives.