Data Sheet
SUNPOWER TECHNOLOGY CORP.
16F.-1, No.150, Jian 1st Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.).
TEL: 886-2-8226-3100 FAX: 886-2-8226-3111
http://www.sunpower.com.tw
E-mail: sunpower@sunpower.com.tw
SPS-S060-xx Series
Copy Right Sunpower Technology Corp. 2009, All Rights Reserved. SPS-S060-xx Rev 1.8
Specifications subject to change without notice. RS-100023 FEB-27-2020
QR0405-1 Rev,:1.0
Features:
* Green mode design, no load < 0.5W
* High efficiency and high reliability
* Built in EMI filter, low ripple noise
* Over voltage protection:Shutdown and latch off
* Over load & short circuit protection:Hiccup mode
* Output voltage ±10% adjustment
* 100% full load burn-in test
* -20℃~70℃ Operating temperature
* UL, cUL, TUV, CB, CE approved
* 3 years warranty
Specification:
INPUT
Voltage
88V ~ 264VAC universal full range or 125V ~ 375VDC.
Frequency
47 ----- 63 Hz
Current
<1.6A@100V AC input, full load condition
Inrush Current (TYP.)
30A@115V , 50A@230V AC input, Cold start at 25℃ ambient
Leakage Current
<0.75mA@264V AC input
OUTPUT
MODEL No.
SPS-S060-3.3
SPS-S060-05
SPS-S060-7.5
SPS-S060-12
SPS-S060-15
SPS-S060-24
SPS-S060-30
SPS-S060-48
Voltage
3.3V
5V
7.5V
12V
15V
24V
30V
48V
Min Load
0A
0A
0A
0A
0A
0A
0A
0A
Max Load
12A
10A
7A
5A
4A
2.5A
2A
1.3A
Output Tolerance
± 3%
± 2%
± 1%
± 1%
± 1%
± 1%
± 1%
± 1%
Ripple Noise MAX.
70mV
70mV
80mV
120mV
150mV
150mV
200mV
200mV
Efficiency (TYP.)
72%
78%
78%
81%
83%
84%
84%
86%
Output MAX.
40W
50W
53W
60W
60W
60W
60W
62W
PROTECTION
Over Voltage
3.8~4.6V
5.8~7.0V
8.6~10.5V
13.8~16.8V
17.3~21.0V
27.6~33.6V
34.5~42.0V
55.2~67.2V
Shutdown and latch off, recover after re-start up.
Over Load & Short Circuit
When power supply over 105%~ 150% max load or short circuit acted, power supply will go into hiccup mode
and recover automatically after the fault is removed.
ELEC. CHAR.
Rise time
<30mS
Hold up time
>60mS@230V, full load condition
Setup time
<1 Sec@100 ~ 240V AC
Green mode function
Power consumption at no load < 0.5W at 240VAC input
ENVIRONMENT
Temperature
Operating: -20 ~ +70℃ ; De-rating: 50 ~ 70℃: 2.5%/℃ ; Storage: -40 ~ +85℃
Humidity
Operating: 20% ~ 90% RH (non condensing) ; Storage: 10% ~ 95% RH (non condensing)
Altitude
6562 ft ( ≒ 2000 m) operating
SAFETY
Withstand voltage
I/P-O/P:3KVAC, I/P-FG:1.8KVAC, O/P-FG:0.5KVAC, 1minute
Isolation resistance
I/P-O/P, I/P-FG, O/P-FG >100MΩ/500VDC at 25℃/ 70% RH
Safety standard
UL 62368-1 2
nd
Edition, 2014-12-01, CAN/CSA C22.2 No. 62368-1-14, 2
nd
Edition, 2014-12, TUV EN 62368-1:2014+A11,
IEC 62368-1:2014 approved
EMC
EMI
EN 55032 CLASS B, FCC CFR 47 PART 15 CLASS B
Compliance to EN61000-3-2 CLASS A, EN61000-3-3
EMS
EN 55024:EN 61000-4-2,3,4,5,6,8,11
OTHERS
Cooling
Natural cooling.
M.T.B.F.
335K hours
Terminal pitch
5P / 9.5mm with plastic cover, 90 deg terminal optional (with MOQ)
Packing
N.W.:0.34Kg / 1pc; 46pcs / 1.22 CUFT / 1 CTN
NOTE
All measurements which not mentioned are based on 230VAC input, output Max at ambient 25℃ / 70%RH
Output tolerance included set up voltage, line regulation and load regulation.
Ripple & noise are measured at 100〜254VAC input with 10〜50℃ condition and 20MHz of bandwidth by using a 10〞〜15〞twisted pair-wire terminated
with a 0.1uF & a 47uF parallel capacitor.
The operating temperature shall follow the de-rating curve in spec
The output load may be requested for decreasing as de-rating curve in spec when low input voltage is under 100VAC.
The power supply is considered a component of end-equipment. The end-equipment must be re-confirmed whether comply with EMC directives.
Single Output
99 x 82 x 35 mm
3.90 x 3.23 x 1.38 inch
Green mode function
CB