Installation and Operation Manual
Form #43219020 
Sept 2012 
1.  Connect to the supply tank or manifold in accordance with the latest edition of National Fuel Gas Code 
(ANSI Z223.1), and local building codes.   Authorities having jurisdiction should be consulted before the 
installation is made. 
2.  All gas supply lines must be located in accordance with the required clearances to combustibles below 
the heater as listed on the nameplate of the heater. 
3.  Pipe joint compounds must be resistant to the action of liquefied petroleum gases. 
4.  Where  local  codes  do  not  prohibit,  a  CSA  or  U.L.  approved  flexible  connector  (minimum  5/8”  I.D.)  is 
recommended between the rigid piping and the heater.  A union and an approved  shut-off valve should 
be  installed  before  the  control  valve  inlet.    The  shut-off  valve  should  be  installed  within  6  feet  of  the 
union. 
8 