Brochure

SIS & SIU Series
PULL THROUGH (NEGATIVE PRESSURE)
7 different BTU sizes and more than 60 different
configurations to custom design your infrared heating
system
Products of combustion are pulled through the
combustion chamber for increased radiant efficiency
and greater safety
Optional decorative grille, elbow and corner reflectors
Sidewall or through the roof venting
Vented or indirect vented operation
Heavy duty draft inducer assembly with permanently
lubricated, totally enclosed and heavy duty ball
bearing motor for maintenance-free operation
30 second pre-purge period before ignition
Heavy duty cast iron burner
Reliable direct spark ignition system and 100%
Gas Shut-Off Safety Control
Step-opening redundant combination gas valve for
quiet ignition and added safety
Up to 50 ft. outside combustion air capability
Diagnostic Monitoring Light System
4" 0. D. heat treated aluminized steel combustion
chamber (10' length)
Standard highly emissive radiant tubes (10' lengths)
Optional aluminized steel radiant tubes (Tough Guy
Option)
5 year limited warranty on all tubes
Up to 75 feet sidewall vent capability
Highly efficient aluminum reflectors
SIR Series
The SunStar Eclipse
SIS Series
A
vailable in multiple configurations:
straight, L, Z and expanded U-configuration,
w
ith lengths up to 50 ft.
SIU Series
P
rovides more uniform radiant
energy distribution. Ideal for high heat
l
oss areas and spot hearing.
Available in BTU sizes from 25,000 to 45,000
Compact length – overall length is 9’2" for ease
of installation
Efficiencies range up to 84.5%
Installation as low as 8' above floor
Optional deflector kit for reduced clearances below
Residential And Commercial
– Certified for residential
garage as well as commercial applications
Vacuum System
Products of combustion are pulled
through the combustion chamber for greater safety ...vir
-
tually eliminates the possibility of combustion gases leak
-
ing into the heated space.
U-Tube Design
Provides uniform emitter tube temper
-
atures and energy distribution on the floor ...unlike
straight tube heaters which are always hotter at the
burner end than at the exhaust end.
Warranty
5-year limited combustion chamber warranty.
Other Features
Heat treated, aluminized steel tubes,
aluminum reflectors with 97% reflectivity rating, direct
spark ignition system with 100% gas safety shut-off con-
trol and 30-second prepurge, diaphragm safety switch
for proof of venting, and system indicator lights.
Model Selection
Model numbers are based on
B
TU/Hr input (e.g., 100,000
BTU/Hr), total emitter length
(e.g., 40 feet), and control
s
uffix for gas type (e.g., nat-
ural gas – Single Stage (e.g.
N
5) or Two Stage (e.g. N7)).
For this example, the model
number for a pull through
(negative pressure) straight
tube heater withSingle Stage
natural gas control would be
SIS100-40-N5. For the same
example, the U-tube heater
model number would be
SIU100-40-N5.
For the same example, the
model number for a push
through (positive pressure)
straight tube heater with a
Two Stage natural gas con-
trol would be SPS100-40-N7.
Using the same example, the
U-tube heater model number
would be SPU100-40-N7.
NATURAL N5 3.5" W.C 5" W.C 14" W.C.
120 VAC
60 HZ
2.4
DIRECT
SPARK
4"
ROUND
4"
ROUND
PROPANE L5 10" W.C. 11" W.C. 14" W.C.
GAS TYPE
C
ONTROL
SUFFIX
B
URNER
PRESSURE
S
UPPLY PRESSURE
MIN MAX
VOLTAGE AMPS
I
GNITION
TYPE
F
LUE
CONN.
F
RESH AIR
CONN.
NATURAL 5" W.C. 5" W.C. 14" W.C.
120 VAC
60 HZ
2.4
DIRECT
SPARK
4"
ROUND
4"
ROUND
PROPANE 10" W.C. 11" W.C. 14" W.C.
GAS
TYPE
BURNER
PRESSURE
SUPPLY PRESSURE
MIN MAX
VOLTAGE
AMPS
IGNITION
TYPE
FLUE
CONN.
FRESH AIR
CONN.
SIR 25 25,000
SIR 35 35,000
SIR 45 45,000
MODEL
NO.
INPUT
BTU/Hr
NOT FOR RESIDENTIAL USE
Tough Guy Option
SunStar also offers a “Tough
Guy” option for more corro-
sive and harsh environments
with heat treated aluminized
steel tubes. For the example
above, the model number for
a pull through (negative pres-
sure) straight tube heater
with the “Tough Guyoption
would be SIS100-40-TG-N5.
Note: SunStar's “Tough Guy”
Option is recommended for
dairy barns, greenhouses,
swimming pools, waste water
treatment plants, chemical
plants and other high humid-
ity or corrosive type environ-
ments. Also the SPS or SPU
series with the “Tough Guy
Option is highly recommend-
ed for car wash applications.
MODELS
SINGLE STAGE
B
TU/HR INPUT
TOTAL EMITTER TUBE LENGTH
1
5' 20' 30' 40' 50' 60'
MIN. MOUNTING
H
EIGHT
AT HORIZONTAL
SIS/U 50 50,000
11 FT
SIS/U 75 75,000
13 FT
SIS/U 100 100,000
14 FT
SIS/U 125 125,000
14 FT
SIS/U 150 150,000
15 FT
SIS/U 175 175,000
16 FT
SIS/U 200 200,000
18 FT