Specification Sheet

end
end
horizontal
front
c
eiling
below
rear
side
ceiling
side
below
© Copyright 2001, SunStar Heating Products, Inc. 10610M Form No. R102
DISTRIBUTED BY
SSuunnSSttaarr
®
INFRARED GAS HEATERS
306 West Tremont Avenue
P.O. Box 36271
Charlotte, North Carolina 28236
Telephone (Toll Free): 1(888)778-6782
Telephone (704) 372-3486
Fax: (704) 332-5843
Email: info@sunstarheaters.com
www.sunstarheaters.com
SunStar Heating Products, Inc. strives to improve quality and performance on a continuing basis and reserves the right to change specifications and materials without notice.
We Make Winters Warmer
Heating Products, Inc.
g
as and electrical
c
onnection
b
urner
b
ox
combustion
chamber
c
ompletely assembled
reflector
draft
inducer
radiant heat
exchanger
smooth
U-bend
Vacuum System - Products of combustion are pulled through the combustion chamber for greater safety
. . . virtually eliminates the possibility of combustion gases leaking into the heated space.
Solid State Ignition System - Reliable electronic direct spark ignition system with 100% gas safety
shut-off control and 30-second prepurge . . . safety and efficiency assurance.
U-Tube Design - Provides uniform emitter tube temperatures and energy distribution on the floor . . . unlike
straight tube heaters which are always hotter at the burner end than at the exhaust end.
Warranty - 5-year limited combustion chamber warranty.
O
ther Features - Heavy-duty combustion chamber, aluminum reflectors with 97% reflectivity rating,
diaphragm safety switch for proof of venting, and system indicator lights.
TECHNICAL FEAT URES
DIMENSIONS
BOTTOM
VIEW
Length: 110"
Width: 18"
Height: 8"
Weight: 74 lbs
MountingS ide Side
ModelA ngleFr ont RearC eilingB elowE nds
SIR(25)0 ˚ 8"8 " 4" 41"*1 2"
SIR(25)4 5˚ 30"4 " 4" 41"*1 2"
SIR(35)(45)0 ˚ 12" 12" 4"5 7"**1 2"
SIR(35)(45)4 40"4 " 4" 57"**1 2"
*33" with deflector **42" with deflector
MODEL SELECTION GUIDELINES
Properly selected heaters will provide the most efficient
operation for your installation.
The models recommended are
selected for a 22' x 28' two-car
or a 26' x 32' three-car insulated
gara ge. Select the model num-
ber corresponding to the geographic location in which
the heater will be installed. Model size is determined by
garage heat loss. Please consult your SunStar distributor to
determine the heat loss for your particular application.
Zone Model
I and II SIR 25
III and VI SIR 35
IV and V SIR 45
For your safety, operate SunStar Eclipse infrared heaters with proper care and observe all safety precautions. Carefully follow the printed installa-
tion, operating and cleaning instructions. Installation and service must be performed by a licensed contractor and conform with local codes.
. Do not store gasoline or combustible products in the vicinity of the heater.
Keep children,clothes
,and draperies a way from the heater. Do not touch the heater or tubes while the heater is in operation.
45 Angle
Maximum
Horizontal
Model Input Model Input
Number BTU/Hour Number BTU/Hour
SIR25 25,000 SIR 45 45,000
SIR35 35,000
Type Burner Supply
Gas Pressure Pressure
Natural 3.5" WC 5 " WC min - 14" WC max
Propane 10" WC 11" WC min - 14" WC max
E
lectrical Requirements: 120 VAC, 60 HZ, 2.4 amps. Flue connection: 4" round. Optional outside combustion air connection: 4" round.
Maintain the listed clearances below to vehicles parked under the heater at all times.
HEATING ZONE MAP
DD
EE
SS
II
GG
NN
CC
EE
RR
TT
II
FF
II
EE
DD
CERTIFIED
Adequate ventilation always must be provided in accordance with codes
TECHNICAL SPECIFICAT IONS
MINIMUM CLEARANCES TO COMBU STIBLES