3. Assembly the reflector onto the tube section. Leave 3space between the tube flange and the reflector for
later mounting of control box and draft inducer.
4. Place the flanges of the control end reflector flush with the end of the first reflector. Secure by sliding speed
clips onto reflector edges. Evenly space 6 speed clips on sides and top of reflectors to provide a snug fit.
Place foot end reflector on the opposite end of the reflector and secure as above.
5. Attach the control box and gaskets to the right-hand control tube flange and secure with (3) 1/4-20 locknuts.
The control box must be mounted with the perforated fresh air plate on top, facing the ceiling.
6. Attach the draft inducer assembly and gaskets to the left-hand draft inducer tube flange and secure with (3)
1/4-20 locknuts. A flue restrictor plate is attached to the draft inducer weld studs. DO NOT DISCARD
RESTRICTOR PLATE and make sure this remains in place while the draft inducer is being attached to the
heater body.