ManualsBrandsSunstone ManualsOutdoor Kitchen Islands84" Grill Island Package with 30" RUBY3B Grill, 10" Single Drop-in Burner, 21" Outdoor Rated Refrigerator, 34" Gas Grill Base Cabinet, 18" Full Height Left Swing Door Cabinet, 30" Appliance Cabinet, 2x Base Cabinet End Panel and 2x Base Cabinet Side Panel
LOCATING BURNER – Installing Under Structure
6
BODILY INJURY: Failure to maintain required clearances creates a fire hazard that
may result in property damage or serious personal injury.
Clearances to Combustible Construction**:
Minimum of 24” from the sides and rear of burner must be maintained to adjacent vertical combustible
construction, above the counter top level. You should take in account that there is a large volume of heat,
and smoke that will exhaust from the rear of the burner. This may discolor or damage unprotected areas,
do not install under unprotected combustible construction without using a fire safe ventilation system.
A 24” minimum clearance must be maintained under the counter top to combustible construction. The
clearance can be modified by a use of an insulated jacket.
** DEFINITION OF COMBUSTIBLE MATERIAL - Any materials of a building structure or decorative
structure made of wood, compressed paper, plant fibers, vinyl/plastic or other materials that are capable of
transferring heat or being ignited and burned. Such material shall be considered combustible even though flame-
proofed, fire-retardant treated, surface-painted, or plastered.
ATTENTION: All Gas Burner Installations MUST HAVE MINIMUM TWO AIR-FLOW VENTS, either
in ELEVATED POSITION for Natural Gas or LOWERED POSITION for Liquid Propane. Your Warranty may
be VOID if island does not meet basic setup requirements.
WARNING: NEVER BUILD YOUR OUTDOOR KITCHEN ISLAND USING COMBUSTIBLE
MATERIALS, MAINTAIN 24” DISTANCES FROM BURNER. USING A BURNER JACKET IS NOT A SURE
BET TO PROTECT COMBUSTIBLE MATERIALS, NEITHER IS THE USE OF HARDY-BOARD.