2.15 ATS7
2.15.1 Description
Connection completion timeout.
This parameter specifies the amount of time, in seconds, that the DCE shall allow between either
answering a call (automatically or by the A command) or completion of signaling of call addressing
information to network (dialing), and establishment of a connection with the remote DCE. If no
connection is established during this time, the DCE disconnects from the line and returns a result
code indicating the cause of the disconnection.
2.15.2 Format
Execution command : ATS7=<value>
2.15.3 Field
Type Short name Parameter/comment
Integer value
1 to 255 Number of seconds in which connection must be
established or call will be disconnected.
2.15.4 Response
Execution command : OK or ERROR
2.16 ATS8
2.16.1 Description
Comma dial modifier time.
This parameter specifies the amount of time, in seconds, that the DCE shall pause, during signaling
of call addressing information to the network (dialing), when a "," (comma) dial modifier is
encountered in a dial string.
2.16.2 Format
Execution command : ATS8=<value>
2.16.3 Field
Type Short name Parameter/comment
Integer value
0 DCE does not pause when ","
encountered in dial string.
1 to 255 Number of seconds to pause.
Recommended default setting
2 DCE pauses two seconds when "," is
encountered.