User's Manual

ST330 User Manual
27
Event Cable Color pin Description
Red: VCC (12V)
Black: Ground
White: Input1. Panic Button
When Input1 goes to GND, then ST330 change Emergency mode.
It reports emergency string by mode 1 in Emergency mode such that
SA200EMG;850000;20081017;07:41:56;00100;+37.478519;+126.886819;000.012;000.00;9;1;0;15.30;
110000;1
Orange: Output1.
Immobilizer activation behaves progressive blocking when vehicle is driving.
The progressive blocking diagram is as below.
The active time of the immobilizer increases 90ms each 4s. After 3minutes, immobilizer is
activated continuously.
When one of output is dedicated to PULSE, it operates as below.
Time for activation and deactivation is configurable by PULSE_ON and PULSE_OFF in Service
Parameter.
Pulse time may have tolerance about dozens of milliseconds.
Active and inactive state is decided by output line number.
Active state of Output 1 is open(Hi-Z) and active state of output 2 is ground.
3.6 Check GPS/GPRS operation and battery charger operation with LEDs.
It takes 3~10 minutes for GPS connected.
Caution: Direction of ST330 is very important when installed in the vehicle. Make sure that
top side of ST330