User's Manual

ST3500 User Manual
8
HDR
DEV_ID
VER
IGNITION
T1
T2
IN1_TYPE
IN2_TYPE
IN3_TYPE
IN1_CHAT
IN2_CHAT
IN3_CHAT
OUT1_TYPE
OUT2_TYPE
OUT1_ACTIVE
OUT2_ACTIVE
PULSE1_NO
PULSE1_ON
PULSE1_OFF
PULSE2_NO
PULSE2_ON
PULSE2_OFF
IN4_TYPE
IN5_TYPE
IN4_CHAT
IN5_CHAT
BAUD
● Definition : Set parameter related event.
Field
Definitions
Unit
Remark
HDR
ST3500EVT
Command type
DEV_ID
6 char.
Device ID
VER
“02”
Protocol Version
T1
String
Sec
Delay for entering idle mode after ignition goes to off
T2
String
Sec
Delay for entering active mode after ignition goes to on
IN1_TYPE
‘0’ ~ ‘7
0 = Falling Edge
1 = Rising Edge
2 = Both Edge (Falling & Rising)
3 = Panic Button
4 = Call1 Button
5 = Call 2 Button
6 = Reserved
7 = Anti-Theft Button
13 = Disable Immobilizer if its activated by jammer
detector.
Default = ‘3’.
Only the device that included voice option (audio circuit)
can be set to Call1 Button or Call2 Button.
IN1_CHAT
String
100ms
Input1 chattering time.
Range : 0 ~ 9999
Default = 3 sec.
If 0, input1 is not checked.