11
IN1_TYPE ‘0’ ~ ‘5’ 0 = Falling Edge
1 = Rising Edge
2 = Both Edge (Falling & Rising)
3 = Panic Button
4 = Call1 Button
5 = Call 2 Button
6 = Reserved
7 = Anti-Theft Button
13 = Disable Immobilizer if it’s activated by jammer
detector.
Default = ‘3’.
Only the device that included voice option (audio circuit)
can be set to ‘Call1 Button’ orCall2 Button’.
IN1_CHAT String 100ms Input1 chattering time.
Range : 0 ~ 9999
Default = 3 sec.
If 0, input1 is not checked.
OUT1_TYPE ‘7’ 7 = No Use
OUT1_ACTIVE ‘0’ or ‘1’
PULSE1_NO ‘0’
PULSE1_ON ‘0’
PULSE1_OFF ‘0’
BAUD ‘0’ 0 = No use
<example>
[command] ST4500EVT;850000;02;1;60;0;3;2;2;30;20;20;1;0;1;0;0;0;0;0;0;0;0;0;0;0;0
[response] ST4500EVT;Res;850000;010;1;60;0;3;8;8;30;0;0;6;6;1;0;0;0;0;0;0;0;8;8;0;0;0
<notes>
** In case of event 4 line model, IN2_TYPE, IN3_TYPE, IN4_TYPE, IN5_TYPE, OUT1_TYPE and OUT2_TYPE
should be ‘No Use’.
Type and chat time of non used event lines are set to ‘No Useand ‘0’ automatically although these filed of
command is set to other value.
4-4. LTE-M1 Parameter Setting
HDR DEV_ID VER SMS_LOCK SMS_MT1 SMS_MT2 SMS_MT3