User's Manual

ST600 User Manual
8
HDR DEV_ID VER IGNITION T1 T2
IN1_TYPE IN2_TYPE IN3_TYPE IN1_CHAT IN2_CHAT IN3_CHAT
OUT1_TYPE OUT2_TYPE OUT1_ACTIVE OUT2_ACTIVE
PULSE1_NO PULSE1_ON PULSE1_OFF PULSE2_NO PULSE2_ON PULSE2_OFF
IN4_TYPE IN5_TYPE IN4_CHAT IN5_CHAT BAUD
● Definition : Set parameter related event.
Field Definitions Unit Remark
HDR “ST600EVT” Command type
DEV_ID 6 char. Device ID
VER “02” Protocol Version
T1 String Sec Delay for entering idle mode after ignition goes to off
T2 String Sec Delay for entering active mode after ignition goes to on
IN1_TYPE ‘0’ ~ ‘7’ 0 = Falling Edge
1 = Rising Edge
2 = Both Edge (Falling & Rising)
3 = Panic Button
4 = Call1 Button
5 = Call 2 Button
6 = Reserved
7 = Anti-Theft Button
13 = Disable Immobilizer if it’s activated by jammer
detector.
Default = ‘3’.
Only the device that included voice option (audio circuit)
can be set to ‘Call1 Button’ or ‘Call2 Button’.
IN1_CHAT String 100ms Input1 chattering time.
Range : 0 ~ 9999
Default = 3 sec.
If 0, input1 is not checked.