Use and Care Manual

SunTouch Mat Do It Yourself Manual
7
Measure the resistance between either of the white or
black leads and ground lead. This measurement should be
open”, usually indicated by an “OL or a “I”. This is the same as
displayed when the test leads are not touching anything.
If there is any change in the reading, record this information
and contact the factory before continuing. This could indicate
damage, test lead problems, or a number of other issues. Try
“pinning the test leads to the cable lead wires against a hard
non-metal surface if the readings continue to fluctuate.
Change the meter to the 20,000 ohms (20 k) range. Measure
between the lead wires of the SunStat sensor. This resistance
varies according to the temperature sensed. Table 3 provides
approximate resistance-to-temperature values for reference.
Temperature Typical Values
55°F (13°C) 17,000 ohms
65°F (18°C) 13,000 ohms
75°F (24°C) 10,000 ohms
85°F (29°C) 8,000 ohms
Table 3 (floor sensor resistance values)
Mat 1 Mat 2 Mat 3
Mat serial number
Mat model number
Mat voltage
Mat resistance range
Sensor
OUT OF THE BOX BEFORE INSTALLATION
Mat white to black
Mat white to ground
Mat black to ground
Sensor
AFTER MAT IS SECURED IN PLACE
Mat white to black
Mat white to ground
Mat black to ground
Sensor
AFTER FLOOR COVERINGS ARE INSTALLED
Mat white to black
Mat white to ground
Mat black to ground
Sensor
Retain this log to retain the warranty! Do not discard!
Table 4 - Mat & Sensor Resistance Log