Submittal Sheet

SunTouch TapeMats are a series resistance heating cable assembly installed
over plywood, backer board, or concrete slab (according to ANSI or TCNA
guidelines), and then embedded in 3/8" (9.5 mm) or greater self-leveling or
polymer-modied thin-set mortar.
SunTouch
®
TapeMat
®
120 and 240 Voltages
SunTouch TapeMats are available in various lengths with voltage options
of 120 or 240 VAC.
Measure and certify the correct wire resistance (ohms) value for the
heating cables, record these readings in the chart provided in the
installation manual.
Use of manufacturer’s alarm meter (LoudMouth
meter) is
recommended during installation.
Clean the suboor.
Lay out and secure SunTouch TapeMat to the oor.
Install the oor sensor in accordance with installation manual.
Install oor coverings as detailed in installation manual.
Installation Guidelines
For Residential and Commercial Applications
Job Name
–––––––––––––––––––––––––––––––––––––––––––
Contractor
––––––––––––––––––––––––––––––––––––––––––––
Job Location
–––––––––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Engineer
–––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No.
–––––––––––––––––––––––––––––––––––
Approval
–––––––––––––––––––––––––––––––––––––––––––––
Representative
––––––––––––––––––––––––––––––––––––––––
ES-ST-TapeMat
Supply Voltage
120VAC, 1-phase
240VAC, 1-phase
Amp Draw
120VAC: 1 amp per 10 sf.
240VAC: 1 amp per 20 sf.
Maximum Circuit Load 20 amps (15 amps with SunStat Control)
Wire Spacing 3" (76 mm) o.c.
Maximum Allowable Temperature
194°F (90°C)
Continuously
EMF
Less than 1 milligauss at 1/2"
(12.7 mm) above surface.
Heating Elements
Oxygen-free copper or
nickel-copper
Insulation ETFE Fluoropolymer
Ground Copper
Double-Sided Tape
3/4" (19 mm) wide, installed
along both edges of mat.
Minimum Allowable Bend Radius 1" (25 mm)
Power Lead Length 10' (2.7 m)
Application
Parameters
Watt Density 3" (76 mm) o.c. 12W/sq ft (129.0 W/m
2
)
Minimum
Polymer-modified
Thinset
3/8" (9.5 mm)
Allowable
Substrate
Backer board over wood subfloor
Polymer-modified setting bed over wood subfloor
Polymer-modified setting bed over concrete slab
Thin slab/self-leveling concrete over
wood subfloor
Thin slab/self-leveling concrete over
concrete slab
Allowable Floor
Coverings
Tile/Stone
Carpet
Hardwood
* Most anti-fracture membranes are approved for use with SunTouch TapeMat.
Contact manufacturer for details on specic products.
Never cut the heating cable or damage it in any way. Use only the attachment
methods as described in the Installation Manual for SunTouch TapeMat as
other methods may damage the heating element.
SunTouch product specications in U.S. customary units and metric are approximate and are provided for refer-
ence only. For precise measurements, please contact SunTouch Technical Service. SunTouch reserves the right to
change or modify product design, construction, specications, or materials without prior notice and without incurring
any obligation to make such changes and modications on SunTouch products previously or subsequently sold.
This Engineering Sheet is not intended to provide full installation instructions
and safety information. In order to avoid property damage or injury, please refer
to the complete installation manual and product safety information provided
with the product.
UL Listed for U.S. under UL Standard 1693 and Canada under
CAN/CSA C22.2 No. 130.2-93.
Listing le number E185866.
Specifications

Summary of content (2 pages)