Installation must be performed by qualified personnel, in accordance with local codes
and standards. A licensed electrician is recommended.
ALWAYS make sure all electrical work is done by qualified persons in accordance with local
building and electrical codes, Section 62 of the Canadian Electrical Code (CEC) Part I, and
the National Electrical Code (NEC), especially Article 424.
ALWAYS use copper only as supply conductors to the thermostat. Do not use aluminum.
ALWAYS seek help if a problem arises. If ever in doubt about the correct installation proce-
dure to follow, or if the product appears to be damaged, the factory must be called before
proceeding with the installation.
Before installing WarmWire, make sure to fully inspect the products and carefully plan the
site. All electrical components selected must be certified for use in your location.
Items Needed
Materials:
WarmWire
®
system
CableStrap
or HeatMatrix
crack-isolation membrane (purchased separately or as part
of a kit from SunTouch).
SunStat
®
Thermostat with floor sensor (SunStat thermostats are UL Listed)
SunStat Relay control if required (SunStat relays are UL Listed)
Control electrical box (UL Listed, extra deep, see control instructions for size and type
required)
Junction electrical box (if required, must be UL Listed and proper size)
Wire nuts (if required, must be UL Listed and proper size)
Flexible or rigid conduit (if required, see Step 2.4, must be UL Listed and proper size)
12-guage or 14-guage electrical wiring cable (UL Listed, see Step 2.1)
Nail plate
Tools:
Digital multi-meter (for ohms testing; must read up to 20,000 ohms (Ω) to measure sensor)
Drill with 1/2" and 3/4" bits
Hammer and chisel
Hot glue gun and hot glue (craft grade)
Wire strippers
Phillips screwdriver
Fish tape
Hole saw
Floor covering installation tools
Phase 1 - Preparations
Floor sensor
is included in
the thermostat
packaging. This must
be installed in the
floor with the cable.