WarmWire Installation Manual

IOM-WR-WW 1528 18 of 32
Phase 5 - Control Installation
STEP 5.1:
If it has not already been done, install an electrical box for the SunStat
®
thermostat and
SunStat Relay. See Step 2.2 for details.
STEP 5.2
Read and follow the instructions included with the SunStat thermostat and SunStat Relay
for complete connection instructions, requirements, and mounting.
STEP 5.3
Make any final connections to the circuit breaker or branch circuit source.
Refer to the installation sheets provided with the controls for proper setting. The system
should now operate as designed.
Please leave this instruction manual, SunStat Control
instructions, and copies of photos of the installed heating system with the end user.
Most laminate and wood floor manufacturers specify their flooring should not be subjected to
temperatures over 82° to 84°F (27° to 28°C). Check with the flooring dealer or manufacturer
and set the thermostat Floor Limit temperature appropriately.
Make sure 120 VAC is supplied to 120 VAC cables and 240 VAC is supplied to 240 VAC
cables. Otherwise, dangerous overheating and possible fire hazard can result.
STEP 5.4
System Start Up
After all controls are installed, do not energize the system, except to briefly test operation
of all components (no longer than 10 minutes). Do not put the system into full operation
until the tile or flooring installer verifies all cement materials are fully cured (typically
two to four weeks). See mortar manufacturer’s instructions for recommended curing time.