specific installation instructions

25 of 36 © 2014 Watts Water Technologies
G
G
SunStat / Relay Connections
Load 1
Line 1
Line 2
Black
Black
White
White
Load 2
Connecting Multiple Cables
Multiple cables can be connected to
a single SunStat or SunStat Relay II.
Refer to Table 2 and Table 5 for details
on calculating the maximum number
of cables per control or relay.
Power
Lead From
WarmWire
Cable 1
WarmWire
Connections
(Junction Box
Near Cables)
SunStat or Relay
Power Supply (120
VAC or 240 VAC)
Power
Lead From
WarmWire
Cable 2
Standard NM
Cable (12 or
14 AWG)
To prevent the risk of personal injury and/or death, do not perform any electrical work
unless qualified to do so. Work should be done with great care and with power turned off
to the circuit being worked on. Follow all local building and electrical codes.
The SunStat is not fully illustrated in these diagrams in order to simplify them. These
diagrams are given only as examples of how to properly connect multiple cables. Care
must be taken not to overfill a box. Be sure to use wire nuts that are the correct size for
the connections being made. Follow all codes for wiring.
All electrical work must be done by a qualified licensed electrician in accordance with local
building and electrical codes, and the National Electrical Code (NEC), especially Article
424 of the NEC, ANSI/NFPA70 and Section 62 of CEC Part 1.