ProMelt Brochure

Driveway plaque: Permanently marks a concrete
slab where a ProMelt system is installed
S u n T o u c h ® P r o M e l t® C a b l e s
ProMelt cable uses the same heating elements as the mats,
but it costs less. It comes on a roll so you can hold it down to
reinforcing wire on the exact spacing needed to melt snow.
S u n T o u c h ® P r o M e l t ® M a t s
ProMelt mats hold the heating elements in place and
they install quickly. All you need is a control and mat.
Mats come in many sizes to t your area and climate.
FREE design assistance
Works under concrete, asphalt, pavers, & tile
Easy to install
Automatic operation
No maintenance
Cables or 2’ and 3 wide mats
Single-point connection
120V, 208V, 240V, and 277V models
Model Number
Dimensions
W(ft) x L(ft)
Coverage
(sq. ft.)
Voltage
Amp
Draw
Total
Output
Model Number
Dimensions
W(ft) x L(ft)
Coverage
(sq. ft.)
Voltage
Amp
Draw
Total
Output
2 Wide ProMelt Mat s - 3 8 W atts/sq. f t. 2 Wide ProMelt Mat s - 3 8 W atts/sq. f t.
SM3812000524 2’ x 5’ 10
120V
3.2 380 SM3824001024 2’ x 10’ 20
240V
3.2 760
SM3812001024 2’ x 10’ 20 6.3 760 SM3824002024 2’ x 20’ 40 6.3 1520
SM3812001524 2’ x 15’ 30 9.5 1140 SM3824003024 2’ x 30’ 60 9.5 2280
SM3812002024 2’ x 20’ 40 12.7 1520 SM3824004024 2’ x 40’ 80 12.7 3040
SM3812002524 2’ x 25’ 50 15.8 1900 SM3824005024 2’ x 50’ 100 15.8 3800
SM3812003024 2’ x 30’ 60 19 2280 SM3824006024 2’ x 60’ 120 19 4560
Model Number
Dimensions
W(ft) x L(ft)
Coverage
(sq. ft.)
Voltage
Amp
Draw
Total
Output
Model Number
Dimensions
W(ft) x L(ft)
Coverage
(sq. ft.)
Voltage
Amp
Draw
Total
Output
2 Wide ProMelt Mat s - 5 0 W atts/sq. f t. 3 Wide ProMelt Mat s - 5 0 W atts/sq. f t.
SM5020800724 2’ x 7’ 14
208V
3.4 700 SM5020800536 3’ x 5’ 15
208V
3.6 750
SM5020801124 2’ x 11’ 22 5.3 1100 SM5020801036 3’ x 10’ 30 7.2 1500
SM5020801424 2’ x 14’ 28 6.7 1400 SM5020801536 3’ x 15’ 45 10.8 2250
SM5020801824 2’ x 18’ 36 8.7 1800 SM5020802036 3’ x 20’ 60 14.4 3000
SM5020802024 2’ x 20’ 40 9.6 2000 SM5020802536 3’ x 25’ 75 18.0 3750
SM5020802424 2’ x 24’ 48 11.5 2400 SM5020803036 3’ x 30’ 90 21.6 4500
SM5020802824 2’ x 28’ 56 13.5 2800
SM5020803424 2’ x 34’ 68 16.3 3400
SM5020803824 2’ x 38’ 76 18.3 3800
SM5020804224 2’ x 42’ 84 20.2 4200
SM5020804824 2’ x 48’ 96 23.1 4800
2 Wide ProMelt Mat s - 5 0 W atts/sq. f t. 3 Wide ProMelt Mat s - 5 0 W atts/sq. f t.
SM5024000824 2’ x 8’ 16
240V
3.3 800 SM5024000536 3’ x 5’ 15
240V
3.1 750
SM5024001224 2’ x 12’ 24 5.0 1200 SM5024001036 3’ x 10’ 30 6.3 1500
SM5024001624 2’ x 16’ 32 6.7 1600 SM5024001536 3’ x 15’ 45 9.4 2250
SM5024002024 2’ x 20’ 40 8.3 2000 SM5024002036 3’ x 20’ 60 12.5 3000
SM5024002424 2’ x 24’ 48 10.0 2400 SM5024002536 3’ x 25’ 75 15.6 3750
SM5024002824 2’ x 28’ 56 11.7 2800 SM5024003036 3’ x 30’ 90 18.8 4500
SM5024003224 2’ x 32’ 64 13.3 3200 SM5024003536 3’ x 35’ 105 21.9 5250
SM5024003624 2’ x 36’ 72 15.0 3600
SM5024004024 2’ x 40’ 80 16.7 4000
SM5024004424 2’ x 44’ 88 18.3 4400
SM5024004824 2’ x 48’ 96 20.0 4800
SM5024005224 2’ x 52’ 104 21.7 5200
2 Wide ProMelt Mat s - 5 0 W atts/sq. f t. 3 Wide ProMelt Mat s - 5 0 W atts/sq. f t.
SM5027700924 2’ x 9’ 18
277V
3.2 900 SM5027701036 3’ x 10’ 30
277V
5.4 1500
SM5027701424 2’ x 14’ 28 5.1 1400 SM5027701536 3’ x 15’ 45 8.1 2250
SM5027701824 2’ x 18’ 36 6.5 1800 SM5027702036 3’ x 20’ 60 10.8 3000
SM5027702424 2’ x 24’ 48 8.7 2400 SM5027702536 3’ x 25’ 75 13.5 3750
SM5027702824 2’ x 28’ 56 10.1 2800 SM5027703036 3’ x 30’ 90 16.2 4500
SM5027703224 2’ x 32’ 64 11.6 3200 SM5027703536 3’ x 35’ 105 19.0 5250
SM5027703624 2’ x 36’ 72 13.0 3600
SM5027704024 2’ x 40’ 80 14.4 4000
SM5027704424 2’ x 44’ 88 15.9 4400
SM5027704824
2’ x 48’ 96 17.3 4800
SM5027705224 2’ x 52’ 104 18.8 5200
SM5027705624
2’ x 56’ 112 20.2 5600
Model Number
Cable
Length
Coverage
@ 3” OC
Coverage
@4” OC
Voltage
Amp
Draw
Total
Output
120VAC ProMelt C a b l e
SC50120008 29 8 10
120V
3.3 400
SC50120015 59 15 20 6.3 750
SC50120020 78 20 26 8.3 1000
SC50120030 118 30 39 12.5 1500
SC50120040 158 40 53 16.7 2000
SC50120053 208 53 69 22.1 2650
208VAC ProMelt C a b l e
SC50208014 55 14 19
208V
3.4 700
SC50208020 78 20 26 4.8 1000
SC50208030 118 30 39 7.2 1500
SC50208035 138 35 46 8.4 1750
SC50208040 158 40 53 9.6 2000
SC50208045 178 45 59 10.8 2250
SC50208055 218 55 72 13.2 2750
SC50208060 238 60 79 14.4 3000
SC50208065 257 65 85 15.6 3250
SC50208075 297 75 98 18.0 3750
SC50208080 317 80 105 19.2 4000
SC50208090 357 90 118 21.6 4500
240VAC ProMelt C a b l e
SC50240015 59 15 20
240V
3.1 750
SC50240025 98 25 33 5.2 1250
SC50240030 118 30 39 6.3 1500
SC50240040 158 40 53 8.3 2000
SC50240045 178 45 59 9.4 2250
SC50240055 218 55 72 11.5 2750
SC50240060 238 60 79 12.5 3000
SC50240065 257 65 85 13.5 3250
SC50240075 297 75 98 15.6 3750
SC50240080 317 80 105 16.7 4000
SC50240090 357 90 118 18.8 4500
SC50240105 417 105 137 21.9 5250
277VAC ProMelt C a b l e
SC50277018 71 18 24
277V
3.2 900
SC50277030 118 30 39 5.4 1500
SC50277035 138 35 46 6.3 1750
SC50277045 178 45 59 8.1 2250
SC50277055 218 55 72 9.9 2750
SC50277060 238 60 79 10.8 3000
SC50277070 277 70 92 12.6 3500
SC50277075 297 75 98 13.5 3750
SC50277080 317 80 105 14.4 4000
SC50277090 357 90 118 16.2 4500
SC50277105 417 105 137 19.0 5250
SC50277115 456 115 150 20.8 5750
Season extending patio heating.
Imagine being able to utilize your outdoor
space for a longer season and being comfort-
able doing so.
With patio heating, radiant comfort can
extend the spring and fall shoulder seasons as
outdoor temperatures drop. Cooler morning
and evening temperatures are held at bay with
supplemental warmth from ProMelt.
Brick Paver: Embed ProMelt
mat or cable in the sand below
pavers, stone or other surfaces.
Asphalt: Lay ProMelt mat or cable between
a rst and second lift of asphalt.
Decorative Surfaces: Embed ProMelt
in a thick-set mortar bed above the slab.
Alternatively, ProMelt can be put in the slab.
Concrete Slab: Secure ProMelt mat or
cable to reinforcing wire or rebar
in the middle of the slab
braided copper ground plane
high-temperature ETFE
element covering
jobsite-tough
high temperature
polyurethane jacket
low-oxygen copper alloy elements
foil shield