3
Panel Dimensions
Suntuf panels use the following corrugation pattern, referred to as profile name Greca 76.
This profile consists of a repeated squared off trapezoidal shape and should not be confused
with the round corrugation profiles of other Palram Americas products. Suntuf panels are
available in widths of 26" (at 8', 10', and 12' lengths) and 49.6" (at 8', 12', and 16' lengths).
Suntuf Accessories
The following accessories are available for use in your Suntuf installation. Note that these accessories are made for use with the Suntuf
profile panels and may not be compatible for use with other Palram Americas Inc.s products.
Safety Measures
The following safety measures should be followed during and after installation of Suntuf panels.
1. Use ladders, crawling boards and other safety equipment required for safe installation. Use all safety measures required according to
local safety regulations.
2. Don’t step on installed panels between support members for fear of falling. Rather, use a sturdy board adequate to
support your weight and long enough to span at least three structural members.
3. Never leave Suntuf panels unattended on the roof until all the required fasteners have been appropriately installed
or the panels secured to the supporting structure.
Design Considerations and Installation Notes
Before You Begin Your Project
Make sure the color of all panels match. Be sure Panel and Horizontal Closure Strip profiles fit together and that all accessories match
the Suntuf profile. Snow, wind and weather loads should be considered when designing the slope degree of your structure. Before
installation, check local building codes for relevant specifications and recommendations. Follow local codes at all times.
Pitch
This is the amount of height in inches the rafter rises over a 12" run for roofing applications. The minimum recommended slope for
Suntuf is 1-½" in 12". When installed at a lower pitch, additional sealing should be applied to ensure weather resistance.
Purlins / Cross Supports
Cross supports (purlins) must be no more than 36" apart for Suntuf. This is the maximum recommended spacing. For most typical
installations however 24" is recommended to give the best balance of economy, light transmission and structural support.
1. Suntuf Ridge Cap Flashing (4'-2" L x 12" W)
2. Suntuf Side Ridge Flashing (4'-2" L x 7" W)
3. Suntuf Wall Connector Flashing (4'-2" L x 8" W)
4. Suntuf Vertical Closure Strip, plastic (7/8" H x 1 3/16" W x 24" L);
Note: limited—and decreasing—availability in wood (7/8" H x 1 3/16" W x 24" L).
5. Suntuf Horizontal Closure Strip, available in plastic (¾" H x 7/8" W x 24" L) and white foam
(¾" H x 7/8" W x 36" L). Note: limited—and decreasing—availability in wood (¾" H x 7/8" W x 24" L).