User's Manual

CrossFire A revolution in RF Transport for In Building Wireless
User Manual
83 Revision 1.0.1
7.4. Alarm Parameters Setup
After completing the radio-frequency channel properties configuration, set up the alarm parameters using the
following procedure:
1. In the WebOMT, select the Engineering tab.
2. Set the statuses of the optical transceiver one by one.
3. If there is an optical path connection, enable the basic device alarms, such as Power Interruption Alarm,
Battery Failure Alarm, MOV Alarm, etc. For alarms related to channel properties, such as the DPLL unlocked
Alarm, LO unlocked Alarm, OP transceiver failure Alarm, etc., only enable those associated with the channels
which have an input signal, to avoid unnecessary alarms. See Figure 7-8 for details.
Wait 3~5 minutes after completing the setup, then query to see if there is a failure alarm for the device. If there is
an alarm, see Section 9 or troubleshooting manual to resolve the issue. Figure 7-8 shows an example of AU Alarm
Parameters Setup.