Product Overview

@sealedunitpartsco
P: 800.333.9125
E: orders@supco.com
F: 800.458.2818
W: supco.com
When condensate IS present, water
pressure moves the ball away from the
seat.
The FCN-HVAC Air-Trap™ is used in residenal or light commercial
applicaons. It allows liquid condensate to drain from HVAC equipment
and simultaneously prevents air from entering or escaping from the
equipment. The FCN also eliminates the geyser effect caused when a
standard P-Trap dries out and condensate begins to form. The FCN
waterless trap requires less than half the height of a standard P-Trap and
operates dry except when condensate is being produced.
FCN
FCN - HVAC Air-Trap
Negative Pressure Waterless Tap
PRODUCT SPECIFICATIONS
Never freezes, never dries
out
Reduces trap height by up
to 60%
Eliminates sludge build-up
Condensate flow up to 1 GPM
at 2” negave pressure
Maximum negave pressure of
WC - 5”
12/2019
When condensate is NOT present, the
ball sets ghtly against the seat.
Comes apart easily for
cleaning
Maximum posive pressure of
WC - 1/2”
Available connecon sizes:
-3/4” or 1/2” with fing
(reducer coupling)