User's Manual
D-2
S
UPERSERVER 6015B-UR/6015B-U/6015B-NTR/6015B-NT User's Manual
Serverboard   
X7DBU (Extended ATX form factor)       
Dimensions: 12 x 13.05 in (305 x 331 mm) 
Chassis   
6015B-UR/6015B-NTR: SC815TQ-R650U Form Factor: 1U rackmount   
6015B-U/6015B-NT: SC815TQ-560U Form Factor: 1U rackmount   
Dimensions: (WxHxD) 17 x 1.7 x 25.6 in. (432 x 43 x 650 mm) 
Weight  
6015B-UR/6015B-NTR: Gross (Bare Bone): 43 lbs. (19.5 kg.)   
6015B-U/6015B-NT: Gross (Bare Bone): 41 lbs. (18.6 kg.)
System Cooling   
Four (4) 4-cm heavy-duty counter-rotating fans     
System Input Requirements   
AC Input Voltage: 100-240 VAC          
Rated Input Current: 8A (115V) to 4A (230V)       
Rated Input Frequency: 50-60 Hz
Power Supply     
6015B-UR/6015B-NTR  
Rated Output Power: 650W (Model# PWS-651-1R)       
Rated Output Voltages: +5V (25A), +3.3V (12A), +12V (54A), +5Vsb (3A) 
6015B-U/6015B-NT  
Rated Output Power: 560W (Model# PWS-561-1H20)     
Rated Output Voltages: +5V (25A), +3.3V (21A), +12V (43.6A), -12V (0.6A), 
+5Vsb (3A)
BTU Rating   
3186 BTUs/hr (for rated output power of 650W)       
2956 BTUs/hr (for rated output power of 560W)
Operating Environment  
Operating Temperature: 10º to 35º C (50º to 95º F)       
Non-operating Temperature: -40º to 70º C (-40º to 158º F)   
Operating Relative Humidity: 8% to 90% (non-condensing)     
Non-operating Relative Humidity: 5 to 95% (non-condensing) 