If the programmed start time is before the end time, output #1 is auto-disabled within a single
day. If the programmed start time is after the end time, the end time will be on the
following day.
The start time and end time cannot be the same.
The auto-disable time can be temporarily paused and restarted using the super user code (see
“Programming the Super User Code” on pages 14~15).
During the output #1 auto-disable time, the super user code can be used to operate output #1
The keypad’s center LED will ash red and amber during the output #1 auto-disable time.
When programming the output #1 auto-disable time, use this general formula:
56 HHMM HHMM #
56
– Program Output #1 Auto-Disable Time
HHMM
– Start Time
HHMM
– End Time
Start Time:
Start time for output #1 auto-disable time.
HH
represents hours and
MM
represents
minutes in the military (24-hour) time format, from 00:00 to 23:59.
End Time:
End time for output #1 auto-disable time.
HH
represents hours and
MM
represents
minutes in the military (24-hour) time format, from 00:00 to 23:59.
Examples (in these examples, assume that the super user code is
2580
):
Set the output #1 auto-disable time from 12:00 PM to 1:00 PM:
56 1200 1300 #
Set the output #1 auto-disable time from 6:30 PM to 7:30 AM:
56 1830 0730 #
Clear the output #1 auto-disable time:
56 #
Temporarily pause and resume the output #1 auto-disable time:
2580 # 8
Activate output #1 during the auto-disable time (i.e. open the protected door):
2580 # 1
Programming the Output #1 Auto-Disable Time (cont.):