User`s manual
6-9
Chapter 6: Using the Configuration Utility
Command Line
sas2ircu <controller #> hotspare [delete] <enclosure:bay>
Parameters
• <controller #> – The index of the controller on which you want to create the hot
spare disk.
• <enclosure:bay> - The enclosure:bay value for the hot spare disk drive. You can get
these values from the output of the DISPLAY command. DOS does not support
addressing by enclosure:bay.
• delete – This optional command deletes the hot spare disk at enclosure:bay.
Program Return Value
0x00 SUCCESS: Command completed successfully.
0x01 FAILURE: Bad command-line arguments or operational failure.
0x02 ADAPTER_NOT_FOUND: Cannot find specified adapter.
STATUS Command
The STATUS command displays the current status of any existing Integrated RAID
volumes and the status of any operation that is currently in progress on the selected
controller. If no operation is in progress, the SAS2IRCU prints a message indicating this
before it exits.
Command Line
sas2ircu <controller #> status
Parameters
• <controller #> – The index of the controller with the volumes whose status you want
to display.
Program Return Value
0x00 SUCCESS: Command completed successfully.
0x01 FAILURE: Bad command-line arguments or operational failure.
0x02 ADAPTER_NOT_FOUND: Cannot find specified adapter.