AS1020P-T(R) AS1020P-8(R) USER’S MANUAL Revision 1.
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. The manufacturer reserves the right to make changes to the product described in this manual at any time and without notice.
Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the AS1020P-T, 1020P-TR, 1020P-8 and 1020P-8R. Installation and maintainance should be performed by experienced technicians only.
AS1020P-T(R)/1020P-8(R) User's Manual Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the 1020P-T(R)/1020P-8(R). Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the H8DSP-i/H8DSP-8 serverboard, including the locations and functions of connections, headers and jumpers.
Preface Notes v
AS1020P-T(R)/1020P-8(R) User's Manual Table of Contents Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... iii Chapter 1: Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ......................
Table of Contents 4-2 General Safety Precautions ............................................................................. 4-2 4-3 ESD Precautions ............................................................................................ 4-3 4-4 Operating Precautions .................................................................................... 4-4 Chapter 5: Advanced Serverboard Setup 5-1 Handling the Serverboard ..........................................................................
AS1020P-T(R)/1020P-8(R) User's Manual DOC Power Header ............................................................................... 5-18 Wake-On-Ring ......................................................................................... 5-18 Wake-on-LAN ......................................................................................... 5-18 5-10 Jumper Settings ............................................................................................. 5-19 Explanation of Jumpers .............
Table of Contents 1020P-TR/1020P-8R: Removing/Replacing the Power Supply ................ 6-9 Chapter 7: BIOS 7-1 Introduction ...................................................................................................... 7-1 7-2 Main Menu ...................................................................................................... 7-2 7-3 Advanced Settings Menu ............................................................................... 7-2 7-4 PCI/PnP Menu ....................
AS1020P-T(R)/1020P-8(R) User's Manual Notes x
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview The AS1020P-T(R)/1020P-8(R) is a high-end server comprised of two main subsystems: the SC816T-(R)700/SC816S-(R)700 1U server chassis and the H8DSP-i/H8DSP-8 dual processor serverboard. Please refer to our web site for information on operating systems that have been certified for use with the 1020PT(R)/1020P-8(R).
AS1020P-T(R)/1020P-8(R) User's Manual 1-2 Serverboard Features At the heart of the 1020P-T(R)/1020P-8(R) lies the H8DSP-i/H8DSP-8, a dual processor serverboard based on Serverworks' HT-2000/1000 chipset. Below are the main features of the H8DSP-i/H8DSP-8 (see Figure 1-1 for a block diagram of the chipset). Processors The H8DSP-i/H8DSP-8 single or dual AMD Opteron 200 series 64-bit processors in 940-pin microPGA ZIF sockets.
Chapter 1: Introduction COM port, a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports. ATI Graphics Controller The H8DSP-i/H8DSP-8 features an integrated ATI video controller based on the Rage XL graphics chip. Rage XL fully supports sideband addressing and AGP texturing. This onboard graphics package can provide a bandwidth of up to 512 MB/sec over a 32-bit graphics memory bus.
AS1020P-T(R)/1020P-8(R) User's Manual PCI Expansion Slots Both chassis support the use of two standard size PCI-X add-on cards (of up to 100 MHz) or two standard size PCI-Express x8 add-on cards (with riser cards). See section 5-6 for details. See section 5-6 for details. Front Control Panel The SC816T-(R)700/SC816S-(R)700's control panel provides you with system monitoring and control. LEDs indicate UID, system power, HDD activity, network activity (2) and overheat/fan failure.
Chapter 1: Introduction Figure 1-1. Serverworks HT-2000/1000 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details.
AS1020P-T(R)/1020P-8(R) User's Manual Notes 1-6
Chapter 2: Server Installation Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get the 1020P-T(R)/1020P-8(R) up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc.
AS1020P-T(R)/1020P-8(R) User's Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing. - This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
AS1020P-T(R)/1020P-8(R) User's Manual 2-4 Installing the System into a Rack This section provides information on installing the 1020P-T(R)/1020P-8(R) into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Chapter 2: Server Installation Installing the Outer Rails Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long brackets to the proper distance so that the rail can fit snugly into the rack.
AS1020P-T(R)/1020P-8(R) User's Manual Installing the Server into the Rack You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3.
Chapter 2: Server Installation Installing the Server into a Telco Rack If you are installing the 1020P-T(R)/1020P-8(R) into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accommodate the width of the telco rack. Figure 2-4.
AS1020P-T(R)/1020P-8(R) User's Manual 2-5 Checking the Serverboard Setup After you install the 1020P-T(R)/1020P-8(R) in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made. 1. Accessing the inside of the system (see Figure 2-5) First, release the retention screws that secure the system to the rack. Grasp the two handles on either side and pull the system straight out until it locks (you will hear a "click").
Chapter 2: Server Installation Figure 2-5.
AS1020P-T(R)/1020P-8(R) User's Manual 2-6 Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SATA/SCSI drives and SATA/SCSI backplane [1020P-T(R)/1020P-8(R), respectively] have been properly installed and all connections have been made. 1. Accessing the drive bays All drives are accessable from the front of the server. For servicing the DVDROM and floppy drives, you will need to remove the top chassis cover.
Chapter 3: System Interface Chapter 3 System Interface 3-1 Overview There are several LEDs on the chassis control panel as well as others on the SATA and SCSI drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
AS1020P-T(R)/1020P-8(R) User's Manual 3-3 Control Panel LEDs The control panel located on the front of the SC816T-(R)700/SC816S-(R)700 chassis has six LEDs, which provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take. UID: This LED turns on when either the front or the rear UID button is pushed. Pushing either button a second time will turn this LED off.
Chapter 3: System Interface HDD: Indicates hard drive activity. On the 1020P-T(R)/1020P-8(R) this light indicates SATA/SCSI and/or CD-ROM drive activity when flashing. Power: Indicates power is being supplied to the system's power supply module(s). With the 1020P-T/8, this LED should always be green when the system is operating. On the 1020P-T/8(R), this LED turns amber in the event of a power supply failure or if a power supply cord is disconnected or loose.
AS1020P-T(R)/1020P-8(R) User's Manual Notes 3-4
Chapter 4: System Safety Chapter 4 System Safety 4-1 Electrical Safety Precautions ! Basic electrical safety precautions should be followed to protect yourself from harm and the AS1020P-T(R)/1020P-8(R) from damage: Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
AS1020P-T(R)/1020P-8(R) User's Manual The power supply power cord must include a grounding plug and must be plugged into grounded electrical outlets. Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarities (see Figure 4-1). The battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
Chapter 4: System Safety it to the rack unit with the retention screws after ensuring that all connections have been made. 4-3 ESD Precautions ! Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards.
AS1020P-T(R)/1020P-8(R) User's Manual 4-4 Operating Precautions ! Care must be taken to assure that the chassis cover is in place when the 1020P-T(R)/1020P-8(R) is operating to ensure proper cooling. Out of warranty damage to the 1020P-T(R)/1020P-8(R) system can occur if this practice is not strictly followed. Figure 4-1.
Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors, memory and heatsinks, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter. Remember to close the chassis completely when you have finished working on the serverboard to protect and cool the system.
AS1020P-T(R)/1020P-8(R) User's Manual 5-2 Processor and Heatsink Installation Exercise extreme caution when handling and installing the proces- ! sor. Always connect the power cord last and always remove it before adding, removing or changing any hardware components. Installing the CPU Backplates Two CPU backplates (BKT-0004) are pre-installed. The backplates prevent the CPU area of the serverboard from bending and provide a base for attaching the heatsink retention modules.
Chapter 5: Advanced Serverboard Setup 4. With the CPU inserted into the socket, inspect the four corners of the CPU to make sure that it is properly installed and flush with the socket. 5. Gently press the CPU socket lever down until it locks in the plastic tab. For a dual-processor system, repeat these steps to install another CPU into the CPU#2 socket. Note: if using a single processor, only CPU 1 DIMM slots are addressable.
AS1020P-T(R)/1020P-8(R) User's Manual 5-3 Mounting the Serverboard into a Chassis All serverboards and motherboards have standard mounting holes to fit different types of chassis. Make sure that the locations of all the mounting holes for both the serverboard and the chassis match. Although a chassis may have both plastic and metal mounting fasteners, metal ones are highly recommended because they ground the serverboard to the chassis. Make sure that the metal standoffs click in or are screwed in tightly.
Chapter 5: Advanced Serverboard Setup 5-4 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The ribbon cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back.
AS1020P-T(R)/1020P-8(R) User's Manual Connecting the Control Panel JF1 contains header pins for various front control panel connectors. See Figure 5-3 for the pin locations of the various front control panel buttons and LED indicators. Please note that even and odd numbered pins are on opposite sides of each header. All JF1 wires have been bundled into single ribbon cable to simplify their connection. Make sure the red wire plugs into pin 1 as marked on the board.
Chapter 5: Advanced Serverboard Setup 5-5 I/O Ports The I/O ports are color coded in conformance with the PC 99 specification. See Figure 5-4 below for the colors and locations of the various I/O ports. Figure 5-4. I/O Ports Note: The external SCSI port is not included on the 1020P-T(R). 5-6 Installing Memory Note: Check the our web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.
AS1020P-T(R)/1020P-8(R) User's Manual which requires modules of the same size and speed to be installed in pairs. You should not mix modules of different sizes and/or speeds. Memory Speed Jumpers Depending on what type of memory you use, you may need to change the XJ4F1 and XJ4F2 (Memory Speed Select) jumpers. See pages 5-10, 5-11 and 5-20 for details. Support The H8DSP-8/H8DSP-i supports single or dual-channel, registered ECC DDR400/333/266/200 SDRAM.
Chapter 5: Advanced Serverboard Setup To Remove: Use your thumbs to gently push each release tab outward to release the DIMM from the slot. Populating Memory Banks for 128-bit Operation CPU1 DIMM1A CPU1 DIMM1B CPU1 DIMM2A CPU1 DIMM2B X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X CPU2 DIMM1A CPU2 DIMM1B X X X X X X X X X X X X CPU2 DIMM2A CPU2 DIMM2B X X X X X X X X X X X X Notes: X indicates a populated DIMM slot.
AS1020P-T(R)/1020P-8(R) User's Manual 5-7 1. Adding PCI Cards PCI slots Your system should come with one or two riser cards to acommodate the use of one or two PCI expansion cards. The number and type of cards supported by each server system is shown below. The 1020P-T(R)/1020P-8(R) supports the use of one (each) standard size (fullheight full-length) 133/100 MHz PCI-X add-on cards or two PCI-Express x8 add-on cards or a combination thereof.
Chapter 5: Advanced Serverboard Setup 5-8 Serverboard Details Figure 5-6.
AS1020P-T(R)/1020P-8(R) User's Manual H8DSP-8/H8DSP-i Quick Reference Jumpers Description Default Setting JBT1 CMOS Clear See Section 2-7 JD1 JI2C1/2 Onboard Spkr En/Disable I2C to PCI Enable/Disable Pins 6-7 (Enabled) Closed (Enabled) JP17 DOC Bus Select Closed (Master) JPA1* JPA2/JPA3* SCSI Enable/Disable SCSI Channel A/B Term. Pins 1-2 (Enabled) Open (Enabled) JPF Power Force On Open (Normal) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPXAO/JPXBO JWD1 PCI-X#1/#2 Freq.
Chapter 5: Advanced Serverboard Setup 5-9 Connector Definitions Primary ATX Power Supply Connector ATX Power 20-pin Connector Pin Definitions (J43) Pin# Definition 11 Ground 1 Ground 12 +5V 2 Ground 13 +5V 3 Ground 14 +3.3V 4 Ground table on the right for the pin definitions 15 +3.3V 5 Ground of the J43 main power connector. 16 +5VSB 6 Ground You must also connect the J15 power connector to your power supply (see below).
AS1020P-T(R)/1020P-8(R) User's Manual HDD LED The HDD (IDE Hard Disk Drive) LED connection is located on pins 13 and 14 of JF1. Attach the IDE hard drive LED cable to display disk activity. HDD LED Pin Definitions (JF1) Pin# Definition 13 Vcc 14 HD Active Refer to the table on the right for pin definitions. NIC1 LED The NIC1 (Network Interface Controller) LED connection is located on pins 11 and 12 of JF1. Attach the NIC1 LED cable to display network activity.
Chapter 5: Advanced Serverboard Setup Power Fail LED Power Fail LED Pin Definitions (JF1) The Power Fail LED connection is located on pins 5 and 6 of JF1. See the table on the right for pin definitions. Pin# Definition 5 Vcc 6 Control Note: This feature is only available when using redundant power supplies. UID Button and LED UID Button/LED Pin Definitions (JF1) A Unit Identifier button/LED is located on pins 3 and 4 of JF1. Attach it to the hardware reset switch on the computer case.
AS1020P-T(R)/1020P-8(R) User's Manual USB2/3 Headers Extra Universal Serial Bus Headers Pin Definitions (USB2/3) Tw o a d d i t i o n a l U S B 2 . 0 h e a d ers (USB2/3) are included on the USB2 Pin # Definition USB3/4 Pin # Definition 1 +5V 1 +5V 2 PO- 2 PO- USB cables (not included) are needed 3 PO+ 3 PO+ for the connections. See the table on 4 Ground 4 Ground the right for pin definitions. 5 Key 5 No connection serverboard. These may be connected to provide front side access.
Chapter 5: Advanced Serverboard Setup Power LED/Speaker PWR LED Connector Pin Definitions (JD1) On JD1, pins 1, 2, and 3 are for the Pin# Definition power LED and pins 4 through 7 are 1 +Vcc for the speaker. See the tables on the right for pin definitions. 2 -Vcc 3 -Vcc Speaker Connector Pin Definitions (JD1) Note: The speaker connector pins are for use with an external speaker. If you wish to use the onboard speaker, you should close pins 6 and 7 with a jumper.
AS1020P-T(R)/1020P-8(R) User's Manual DOC Power Header DOC Power Header Pin Definitions (JWF1) JWF1 is a power header for a DOC Pin# Definition (Disk-On-Chip) device. Connect the 1 +5V appropriate cable here to provide power to a DOC device on your sys- 2 Ground 3 Signal tem. See the table on the right for pin definitions. Wake-On-Ring The Wake-On-Ring header is designated JWOR. This function allows your computer to receive and "wakeup" by an incoming call to the modem when in suspend state.
Chapter 5: Advanced Serverboard Setup 5-10 Jumper Settings Explanation of Jumpers To modify the operation of the serverboard, jumpers can be used to 3 2 1 3 2 1 Connector Pins choose between optional settings. Jumpers create shorts between two pins to change the function of the Jumper connector. Pin 1 is identified with a square solder pad on the printed circuit board. See the diagram at right for an example of jumping pins 1 and 2. Refer to the serverboard layout page for jumper locations.
AS1020P-T(R)/1020P-8(R) User's Manual PCI-X#1/#2 Frequency Select PCI-X#1/#2 Frequency Select Jumper Settings (JXAO/JXBO) Jumpers JXAO and JXBO are used to set the speed of PCI-X slots 1 and Jumper Setting 2, respectively. The recommended (default) setting is open for Auto. Pins 1-2 66 MHz PCI-X Pins 2-3 66 MHz PCI Open Auto See the table on the right for jumper Definition settings.
Chapter 5: Advanced Serverboard Setup SCSI Controller Enable/ Disable (H8DSP-8 only) Jumper JPA1 is used to enable or disable the Adaptec AIC-7902W SCSI controller. The default setting is on pins 1-2 to enable SCSI. See the table on SCSI Enable/Disable Jumper Settings (JPA1) Both Jumpers Definition Pins 1-2 Enabled Pins 2-3 Disabled right for jumper settings.
AS1020P-T(R)/1020P-8(R) User's Manual I2C to PCI Enable/Disable JI2C1/2 pair of jumpers allow you to connect the System Management Bus I2C to PCI Enable/Disable Jumper Settings (JI2C1/JI2C2) to any one of the PCI slots. The default setting is closed for both jumpers to en- Jumper Setting able the connection. Both connectors must have the same setting (JI2C1 is Definition Closed Enabled Open Disabled for data and JI2C2 is for the clock). See the table on right for jumper settings.
Chapter 5: Advanced Serverboard Setup SCSI Activity LEDs (H8DSP8 only) SCSI Channel Activity LEDs (DA1/DA2) There are two SCSI activity LEDs on the serverboard. When illuminated, State System Status On SCSI Channel Active Off SCSI Channel Inactive DA1 indicates activity on SCSI channel A and DA2 indicates activity on SCSI channel B. POST Code LEDs Eight surface-mounted LEDs are located near one end of the 1UIPMI slot. These LEDs are used to provide POST code information.
AS1020P-T(R)/1020P-8(R) User's Manual 5-12 Floppy, IDE, SCSI and SATA Drive Connections Note the following when connecting the floppy and hard disk drive cables: • The floppy disk drive cable has seven twisted wires. • A red mark on a wire typically designates the location of pin 1. • A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives.
Chapter 5: Advanced Serverboard Setup IDE Connectors IDE Drive Connectors Pin Definitions (JIDE#1) There are no jumpers to con- Pin# Definition figure the onboard IDE connec- 1 Reset IDE 2 Ground tor. See the table on the right for pin definitions.
AS1020P-T(R)/1020P-8(R) User's Manual SCSI Connectors (H8DSP-8 only) Ultra320 SCSI Drive Connectors Pin Definitions (JA1/JB1) Pin# Definition Pin # Definition Refer to the table at right for 1 +DB (12) 35 -DB (12) pin definitions for the Ultra320 2 +DB (13) 36 -DB (13) SCSI connectors located at JA1 and JB1.
Chapter 5: Advanced Serverboard Setup SATA 4-Port Connector Pin Definitions (JSM1) SATA Connector Pin# Definition Pin # Definition 1 Ground 2 RXD+ There are no jumpers to con- 3 RXD- 4 Ground figure the SATA connector. 5 TXD- 6 TXD+ JSM1 is a 4-port connector that includes designations SATA0 7 Ground 8 RX1+ 9 RX1- 10 Ground through SATA3. See the table on the right for pin definitions. This is a four-port connector.
AS1020P-T(R)/1020P-8(R) User's Manual Notes 5-28
Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC816T-(R)700/SC816S-(R)700 chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step. Tools Required The only tool you will need to install components and perform maintenance is a Philips screwdriver.
AS1020P-T(R)/1020P-8(R) User's Manual Figure 6-1. Chassis: Front and Rear Views Slim DVD-ROM Drive Slim Floppy Drive UID Button and LED SATA/SCSI Drives GLAN Ports USB0/1 Ports PCI Expansion Slot Mouse/Keyboard Ports System LEDs COM Port VGA Port Control Panel Main Power Power Supply Modules UID Button/LED External SCSI Port Note: The external SCSI port is not included on the 1020P-T/1020P-TR. On the 1020P-8/1020P-T, the power supply module on the left is a dummy module.
Chapter 6: Advanced Chassis Setup 6-3 System Fans Four 5-cm fans provide the cooling for the 1020P-T(R)/1020P-8(R). Each fan unit is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airflow and helps dampen vibration levels. These fans can adjust their speed according to the heat level sensed in the system, which results in more efficient and quieter fan operation.
AS1020P-T(R)/1020P-8(R) User's Manual Figure 6-2. Removing a Fan 6-4 Drive Bay Installation/Removal Accessing the Drive Bays SATA and SCSI Drives: Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace SATA or SCSI drives. Proceed to the next step for instructions. Note: You must use standard 1" high, SATA/SCSI drives in the 1020P-T(R)/1020P8(R).
Chapter 6: Advanced Chassis Setup SATA and SCSI Drive Installation 1. Mounting a drive in a drive carrier The SATA/SCSI drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airflow for the drive bays. For this reason, even empty carriers without drives installed must remain in the chassis.
AS1020P-T(R)/1020P-8(R) User's Manual 2. Installing/removing hot-swap SATA/SCSI drives The SATA/SCSI drive carriers are all easily accessible at the front of the chassis. These hard drives are hot-pluggable, meaning they can be removed and installed without powering down the system. To remove a carrier, push the release button located beside the drive LEDs. Then swing the colored handle fully out and use it to pull the unit straight out (see Figure 6-4).
Chapter 6: Advanced Chassis Setup DVD/CD-ROM and Floppy Drive Installation The top cover of the chassis must be opened to gain full access to the DVD/CDROM and floppy drive bays. The 1020P-T/1020P-8 accomodates only slim DVD/ CD-ROM and floppy drives. Side mounting brackets are needed to mount the DVD/CD-ROM drive in the server. You must power down the system before installing or removing a floppy or DVD/ CD-ROM drive. First, release the retention screws that secure the server unit to the rack.
AS1020P-T(R)/1020P-8(R) User's Manual 6-5 Power Supply 1020P-T/1020P-8 The 1020P-T/1020P-8 has a single 700 watt cold-swap power supply, which is auto-switching capable. This enables it to automatically sense and operate with a 100v - 240v input voltage. An amber light will be illuminated on the power supply when the power is off. An illuminated green light indicates that the power supply is operating.
Chapter 6: Advanced Chassis Setup 1020P-TR/1020P-8R The 1020P-TR/1020P-8R has a redundant 700 watt redundant power supply configuration consisting of two hot-swappable power modules. The power supply modules have an auto-switching capability, which enables them to automatically sense and operate with a 100V - 240V input voltage. Power Supply Failure If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption.
AS1020P-T(R)/1020P-8(R) User's Manual Figure 6-5.
Chapter 7: BIOS Chapter 7 BIOS 7-1 Introduction This chapter describes the AMIBIOS™ Setup utility for the H8DSP-8/H8DSP-i. The AMI ROM BIOS is stored in a flash chip and can be easily upgraded using a floppy disk-based program. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual. Please refer to the Manual Download area of the our web site
AS1020P-T(R)/1020P-8(R) User's Manual 7-2 Main Menu When you first enter AMI BIOS Setup Utility, you will see the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main Setup screen provides you with a system overview, which includes the version, built date and ID of the AMIBIOS, the type, speed and number of the processors in the system and the amount of memory installed in the system.
Chapter 7: BIOS IDE Configuration Onboard PCI IDE Controller The following options are available to set the IDE controller status: Disabled will disable the controller. Primary will enable the primary IDE controller. There is no Secondary option since only one IDE slot is provided on the board. Primary IDE Master/Slave Highlight one of the two items above and press to access the submenu for that item. Type Select the type of device connected to the system.
AS1020P-T(R)/1020P-8(R) User's Manual data transfer rate of 3.3 MBs. Select 1 to allow AMI BIOS to use PIO mode 1 for a data transfer rate of 5.2 MBs. Select 2 to allow AMI BIOS to use PIO mode 2 for a data transfer rate of 8.3 MBs. Select 3 to allow AMI BIOS to use PIO mode 3 for a data transfer rate of 11.1 MBs. Select 4 to allow AMI BIOS to use PIO mode 4 for a data transfer rate of 16.6 MBs. This setting generally works with all hard disk drives manufactured after 1999.
Chapter 7: BIOS Floppy Configuration Floppy A Move the cursor to these fields via up and down keys to select the floppy type. The options are Disabled, 360 KB 5 1/4", 1.2 MB 5 1/4", 720 KB 3½", 1.44 MB 3½”, and 2.88 MB 3½". Floppy B Move the cursor to these fields via up and down keys to select the floppy type. The options are Disabled, 360 KB 5 1/4", 1.2 MB 5 1/4", 720 KB 3½", 1.44 MB 3½”, and 2.88 MB 3½".
AS1020P-T(R)/1020P-8(R) User's Manual KBC Clock Source The options for the KBC clock source are 8 MHz, 12 MHz and 16 MHz. Restore on AC Power Loss This setting allows you to choose how the system will react when power returns after an unexpected loss of power. The options are Power Off and Last State. Watch Dog Timer This setting is used to enable or disabled the Watch Dog Timer function. It must be used in conjunction with the Watch Dog jumper (see Chapter 2). Options are Disabled and Enabled.
Chapter 7: BIOS ACPI APIC Support Select "Enabled" to allow the ACPI APIC Table Pointer to be included in the RSDT pointer list. The options are Enabled and Disabled. ACPI OEMB Table This setting when enabled will include an OEMB table pointer to pointer lists. Options are Enabled and Disabled. Headless Mode Select "Enabled" to activate the Headless Operation Mode through ACPI. The options are Enabled and Disabled.
AS1020P-T(R)/1020P-8(R) User's Manual CPU0: CPU1 HT Link Width The HT link will run at the width specified in this setting. Options are Auto, 2 bit, 4 bit, 8 bit and 16 bit. CPU0: HT2000 HT Link Speed The HT link will run at the speed specified in this setting if it is slower than or equal to the system clock and if the board is capable. Options are Auto, 200 MHz, 400 MHz, 600 MHz, 800 MHz and 1 GHz. CPU0: HT2000 HT Link Width The HT link will run at the width specified in this setting.
Chapter 7: BIOS Remote Access Configuration Remote Access Use this setting to Enable or Disable remote access. If Enabled is selected, you can select a Remote Access type. USB Configuration This screen will display the module version and all USB enabled devices. Legacy USB Support Select "Enabled" to enable the support for USB Legacy. Disable Legacy support if there are no USB devices installed in the system. The options are Enabled and Disabled. USB 2.
AS1020P-T(R)/1020P-8(R) User's Manual System Fan Monitor Fan Speed Control Modes This feature allows the user to determine how the system will control the speed of the onboard fans. If the option is set to "3-pin fan", the fan speed is controlled based upon the CPU die temperature. When the CPU die temperature is higher, the fan speed will be higher as well. If the option is set to "4-pin", the fan speed will be controlled by the Thermal Management Settings pre-configured by the user with this setting.
Chapter 7: BIOS Palette Snooping Select "Enabled" to inform the PCI devices that an ISA graphics device is installed in the system in order for the graphics card to function properly. The options are Enabled and Disabled. PCI IDE BusMaster Set this value to allow or prevent the use of PCI IDE busmastering. Select "Enabled" to allow AMI BIOS to use PCI busmaster for reading and writing to IDE drives. The options are Disabled and Enabled.
AS1020P-T(R)/1020P-8(R) User's Manual 7-5 Boot Menu Boot Settings Configuration Quick Boot If Enabled, this option will skip certain tests during POST to reduce the time needed for the system to boot up. The options are Enabled and Disabled. Quiet Boot If Disabled, normal POST messages will be displayed on boot-up. If Enabled, this display the OEM logo instead of POST messages. Add-On ROM Display Mode This setting controls the display of add-on ROM (read-only memory) messages.
Chapter 7: BIOS Boot Device Priority This feature allows the user to prioritize the sequence for the Boot Device with the devices installed in the system. The default settings (with generic names) are: · 1st Boot Device – Removeable drive (e.g. floppy drive) · 2nd Boot Device – CD/DVD · 3rd Boot Device – Hard drive · 4th Boot Device – LAN Hard Disk Drives This feature allows the user to prioritize the Boot sequence from available hard drives.
AS1020P-T(R)/1020P-8(R) User's Manual 7-6 Security Menu AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set first. Change Supervisor Password Select this option and press to access the sub menu, and then type in the password. Change User Password Select this option and press to access the sub menu, and then type in the password. Boot Sector Virus Protection This option is near the bottom of the Security Setup screen.
Chapter 7: BIOS 7-7 Chipset Menu North Bridge Configuration Memory Configuration Memclock Mode This setting determines how the memory clock is set. Auto has the memory clock set by the code and Limit allows the user to set a standard value. MCT Timing Mode Sets the timing mode for memory. Options are Auto and Manual. User Configuration Mode Options are Auto and Manual. Bank Interleaving This setting is used to determine whether bank interleaving is to be employed.
AS1020P-T(R)/1020P-8(R) User's Manual ECC Configuration DRAM ECC Enable DRAM ECC allows hardware to report and correct memory errors automatically. Options are Enabled and Disabled. MCA DRAM ECC Logging When "Enabled", MCA DRAM ECC logging and reporting is enabled. Options are Enabled and Disabled. ECC Chip Kill Allows the user to Enable or Disable ECC Chip Kill. DRAM Scrub Redirect Allows system to correct DRAM ECC errors immediately, even with background scrubbing on.
Chapter 7: BIOS HT2000 System I/O Configuration EXB_B Split to 2 (x4) Enable or Disable EXB_B Split to 2. EXB_C Split to 2 (x4) Enable or Disable EXB_C Split to 2. HT1000 SouthBridge Configuration HIDE XIOAPIC PCI Functions The options are Yes and No. 7-8 Exit Menu Select the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
AS1020P-T(R)/1020P-8(R) User's Manual Load Optimal Defaults To set this feature, select Load Optimal Defaults from the Exit menu and press . Then Select "OK" to allow BIOS to automatically load the Optimal Defaults as the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications. Load Fail-Safe Defaults To set this feature, select Load Fail-Safe Defaults from the Exit menu and press .
Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen. Fatal errors are those which will not allow the system to continue the boot-up procedure.
AS1020P-T(R)/1020P-8(R) User's Manual Notes A-2
Appendix B: BIOS POST Checkpoint Codes Appendix B BIOS POST Checkpoint Codes When AMIBIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, diagnostic equipment can be attached to the computer to read I/O port 0080h. B-1 Uncompressed Initialization Codes The uncompressed initialization checkpoint codes are listed in order of execution: Checkpoint Code Description D0h The NMI is disabled. Power on delay is starting.
AS1020P-T(R)/1020P-8(R) User's Manual B-2 Bootblock Recovery Codes The bootblock recovery checkpoint codes are listed in order of execution: Checkpoint Code Description E0h The onboard floppy controller if available is initialized. Next, beginning the base 512 KB memory test. E1h Initializing the interrupt vector table next. E2h Initializing the DMA and Interrupt controllers next. E6h Enabling the floppy drive controller and Timer IRQs. Enabling internal cache memory.
Appendix B: BIOS POST Checkpoint Codes B-3 Uncompressed Initialization Codes The following runtime checkpoint codes are listed in order of execution. These codes are uncompressed in F0000h shadow RAM. Checkpoint Code Description 03h The NMI is disabled. Next, checking for a soft reset or a power on condition. 05h The BIOS stack has been built. Next, disabling cache memory. 06h Uncompressing the POST code next. 07h Next, initializing the CPU and the CPU data area.
AS1020P-T(R)/1020P-8(R) User's Manual Checkpoint Code Description 25h Interrupt vector initialization is done. Clearing the password if the POST DIAG switch is on. 27h Any initialization before setting video mode will be done next. 28h Initialization before setting the video mode is complete. Configuring the monochrome mode and color mode settings next. 2Ah Bus initialization system, static, output devices will be done next, if present. See the last page for additional information.
Appendix B: BIOS POST Checkpoint Codes Checkpoint Code Description 4Ch The memory below 1 MB has been cleared via a soft reset. Clearing the memory above 1 MB next. 4Dh The memory above 1 MB has been cleared via a soft reset. Saving the memory size next. Going to checkpoint 52h next. 4Eh The memory test started, but not as the result of a soft reset. Displaying the first 64 KB memory size next. 4Fh The memory size display has started. The display is updated during the memory test.
AS1020P-T(R)/1020P-8(R) User's Manual Checkpoint Code Description 86h The password was checked. Performing any required programming before WINBIOS Setup next. 87h The programming before WINBIOS Setup has completed. Uncompressing the WINBIOS Setup code and executing the AMIBIOS Setup or WINBIOS Setup utility next. 88h Returned from WINBIOS Setup and cleared the screen. Performing any necessary programming after WINBIOS Setup next. 89h The programming after WINBIOS Setup has completed.
Appendix B: BIOS POST Checkpoint Codes Checkpoint Code Description A9h Returned from adaptor ROM at E000h control. Performing any initialization required after the E000 option ROM had control next. Aah Initialization after E000 option ROM control has completed. Displaying the system configuration next. Abh Uncompressing the DMI data and executing DMI POST initialization next. B0h The system configuration is displayed. B1h Copying any code to specific areas.
AS1020P-T(R)/1020P-8(R) User's Manual Notes B-8
Appendix C: System Specifications Appendix C System Specifications Processors Single or dual AMD Opteron 200 series 64-bit processors in 940-pin microPGA ZIF sockets Note: Please refer to our web site for a complete listing of supported processors.
AS1020P-T(R)/1020P-8(R) User's Manual Expansion Slots One (of each) standard size (full-height full-length) 133/100 MHz PCI-X addon cards or two PCI-Express x8 add-on cards or a combination thereof. (See Section 5-6 for details) Serverboard [1020P-T(R)/1020P-8(R)] Model: H8DSP-i/H8DSP-8 (Extended ATX) Dimensions: 9.6" x 16.
Appendix C: System Specifications Operating Environment Operating Temperature: 10º to 35º C (50º to 95º F) Non-Operating Temperature: -40º to 70º C (-40º to 158º F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-Operating Relative Humidity: 5 to 95% (non-condensing) Regulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
AS1020P-T(R)/1020P-8(R) User's Manual Notes C-4