Chapter 4: Chassis Setup and Maintenance
4-7  Checking the Server's Air Flow
Checking the Air Flow
1.  Make sure  there are  no  objects  to  obstruct airow  in  and out  of  the  server. In 
addition, if you are using a front bezel, make sure that the bezel's lter is replaced 
periodically. 
2.  Do  not  operate  the  server  without drives or  drive trays in  the drive bays. Use 
only the recommended server parts.
3. Make sure that no wires or foreign objects obstruct airow through the chassis. 
Pull all excess cabling out of the airow path or use shorter cables.
The  control  panel  LEDs  inform  you  of  system  status.  See  “Chapter  3:  System 
Interface” for details on the LEDs and the control panel buttons.
In most cases, the chassis power supply and fans are pre-installed. If you need to 
install fans continue to the Systems Fan section of this chapter. If the chassis will be 
installed into a rack, continue to the next chapter for rack installation instructions