User's Manual (1.0)

2-6
SUPERSERVER 6017TR-TQF/TFF/TF User's Manual
Outer Rack Rails
Outer rails attach to the rack and hold the chassis in place.
Installing the Outer Rails to the Rack (Figure 2-3)
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2. Adjust both the short and long brackets to the proper distance so that the rail
ts snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
4. Repeat steps 1-4 for the left outer rail.
Installing the Chassis into a Rack (Figure 2-4)
1. Con rm that chassis includes the inner rails (A) and rail extensions (B). Also,
con rm that the outer rails (C) are installed on the rack.
2. Line chassis rails (A and B) with the front of the rack rails (C).
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs "click".
4. (Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.
Figure 2-3. Assembling the Outer Rails
Secure to the
Front of the Rack
Secure to the Rear
of the Rack
Attach Outer Racks
together