Installing the Server into the Rack
Locate a pair of front (short) and rear (long) brackets that were included with
your rack mounting hardware. Note that the brackets are marked with up/front
arrows (front) and up/rear arrows (rear). Secure the short front bracket (A in
Figure 2-3) to the outer rail with two M4 x 4 mm roundhead screws. Locate
the two buttons on the outer rail (B in Figure 2-3) and attach the rear (long)
bracket to it by sliding the opening of the rear rail through the button. Measure
the depth of your rack and adjust the length of the rails accordingly. Repeat
the same steps to install the other outer rail on the chassis. Secure both
outer rail assemblies to the rack using M5 x 12 mm flathead screws and M5
washers.
You are now ready to install the server into the rack. Slide the chassis into
the rack as shown in Figure 2-4. The chassis may not slide into the rack
smoothly or easily when installed the first time. Some adjustment to the slide
assemblies might be needed for easy installation.)
When the server has been pushed completely into the rack, you should hear
the locking tabs "click". You will need to release the safety taps on both sides
of the chassis in order to completely remove the chassis out of the rack.
A
B
Screws
Figure 2-3. Assembling the Rack Rails