2-5 Checking the Serverboard Setup
After you install the 6034H-X8R in the rack, you will need to open the unit to
make sure the serverboard is properly installed and all the connections
have been made.
1. Accessing the inside of the 6034H-X8R (see Figure 2-5):
First, release the retention screws that secure the unit to the rack.
Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click"). Next, depress the two buttons on the top
of the chassis to release the top cover. You can then lift the top cover
from the chassis to gain full access to the inside of the server.
2. Check the CPUs (processors):
You may have one or two processors already installed into the serverboard.
Each processor needs its own heatsink. See Chapter 5 for instructions on
processor and heatsink installation.
3. Check the system memory:
Your 6034H-X8R server system may have come with system memory
already installed. Make sure all DIMMs are fully seated in their slots. For
details on adding system memory, refer to Chapter 5.
4. Installing add-on cards:
If desired, you can install add-on cards to the system. See Chapter 5 for
details on installing PCI add-on cards.
5. Check all cable connections and airflow:
Make sure all power and data cables are properly connected and not
blocking the chassis airflow. Also make sure that no cables are posi-
tioned in front of the fans. See Chapter 5 for details on cable connec-
tions.