User`s manual

2-8
SUPERSERVER 6018R-WTR(T) USER'S MANUAL
Figure 2-5. Accessing the Inside of the System
2-6 Checking the Serverboard Setup
After you install the SuperServer 6018R-WTR(T) in the rack, you will need to
open the top cover to make sure the serverboard is properly installed and all the
connections have been made.
Accessing the Inside of the System (Figure 2-5)
1. First, grasp the two handles on either side and pull the system straight out
until it locks (you will hear a "click").
2. Depress the two buttons on the top of the chassis to release the top cover
(1).
3. Push the cover away from you (toward the rear of the chassis) until it stops
(2). You can then lift the top cover from the chassis to gain full access to the
inside of the server. See Figure 2-5.
4. To remove the system from the rack completely, depress the locking tabs in
the chassis rails (push the right-side tab down and the left-side tab up) to
continue to pull the system out past the locked position.