User`s manual

7-22
SUPERSERVER 7046T-3R User's Manual
Subnet Mask
This item displays the current subnet mask setting for your IPMI connection.
VLAN Tagging
Select Enabled to enable VLAN (Virtual LAN) Tagging support which allows mul-
tiple networks to transparently share the same physical network without leaking
information between the bridged networks. VLAN Tagging complies with the IEEE
802.1Q Standards. The options are Enabled and Disabled.
XSEL PEF Con guration
PEF Con guration
Set this feature to con gure the Platform Event Filter (PEF). PEF interprets BMC
events and performs actions based on pre-determined settings or 'traps' under
IPMI 1.5 speci cations. Powering the system down or sending an alert when a
triggering event is detected. The default is Disabled.
The following will appear if PEF Support is set to Enabled.
PEF Action Global Control
These are the different actions based on BMC events. The options are Alert,
Power Down, Reset System, Power Cycle, OEM Action, Diagnostic Interface.
Alert Startup Delay
This feature inserts a delay during startup for PEF alerts. The options are En-
abled and Disabled.
PEF Alert Startup Delay
This sets the pre-determined time to delay PEF alerts after system power-ups
and resets. Refer to Table 24.6 of the IPMI 1.5 Speci cation for more information
at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.
Startup Delay
This feature enables or disables startup delay. The options are Enabled and
Disabled.
PEF Startup Delay
This sets the pre-determined time to delay PEF after system power-ups and
resets. Refer to Table 24.6 of the IPMI 1.5 Speci cation for more information at
www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.