UPERSERVER 6014H-32 User's Manual
2-5 Checking the Serverboard Setup
After you install the 6014H-32 in the rack, you will need to open the unit to make
sure the serverboard is properly installed and all the connections have been
made.
1. Accessing the inside of the 6014H-32 (see Figure 2-5)
First, release the retention screws that secure the unit to the rack. Grasp the two
handles on either side and pull the unit straight out until it locks (you will hear
a "click"). Next, depress the two buttons on the top of the chassis to release
the top cover. There is a large rectangular recess in the middle front of the top
cover to help you push the cover away from you until it stops. You can then lift
the top cover from the chassis to gain full access to the inside of the server.
2. Check the CPUs (processors)
You should have one or two processors already installed into the serverboard.
Each processor needs its own heatsink. See Chapter 5 for instructions on pro-
cessor and heatsink installation.
3. CPU Speed
The CPU speed should automatically be detected so you will not need to change
any jumpers or settings in the BIOS Setup utility.
4. Check the system memory
Your 6014H-32 server system may have come with system memory already
installed. Make sure all DIMMs are fully seated in their slots. For details on
adding system memory, refer to Chapter 5.
5. Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for details
on installing PCI add-on cards.
6. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking
the chassis air ow. See Chapter 5 for details on cable connections.