6-5 Power Supply
The SuperServer 6014H-32 has a single 500 watt power supply, which is auto-
switching capable. This enables it to automatically sense and operate at a 100v
to 240v input voltage. An amber light will be illuminated on the power supply
when the power is off. An illuminated green light indicates that the power supply
is operating.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need to replace
the unit. Replacement units can be ordered directly from Supermicro (see contact
information in the Preface). As there is only one power supply unit in the 6014H-32,
power must be completely removed from the server before removing and replacing
the power supply unit for whatever reason.
Removing/Replacing the Power Supply
1. Removing the power supply
First turn the power switch on the control panel off, then unplug the power cord
from the system. Remove the chassis cover by pressing the two release buttons
on the top of the chassis (near the front) and push the chassis top rearward about
one inch. To remove the failed power unit, push the beige colored release tab to
the right and then carefully lift the unit up about 1/2 inch only. If you lift too high,
you may damage the power distribution board that the other end of the unit is
connected to. Then, pull the power unit straight back to unplug it from the power
distribution board. See Figure 6-6.
2. Installing a new power supply
Replace the failed unit with another unit of the same input voltage, output voltage
and wattage. It is highly recommended to replace it with exactly the same model
power supply. Carefully insert the new unit into position to plug it into the power
distribution board, making sure you are not holding it at too great an angle, which
may damage the power distribution board. Push it completely into the power
distribution board and seat it in the chassis. When correctly installed it should be
laying fl at - make sure the end of the power supply is not sitting on the stop in the
chassis. Reconnect the power cord, replace the chassis top cover and reposition
the unit back into the rack. Finish by depressing the power button on the chassis
front control panel.