Datasheet
Chapter 6: Advanced Chassis Setup
6-3
6-3 System Fans
Four 4-cm high-performance 12500 rpm fans provide the cooling for the SuperServer
6015C-M3/6015C-MT. The chassis includes air seals under the fans and at the
chassis cross section, which separates the drive bay area from the serverboard
area of the chassis to promote better airfl ow. It is highly important that the air seal
is properly installed and making a good seal in order for the cooling air to circulate
properly through the chassis.
Fan speed may be controlled by a setting in BIOS (see Chapter 7).
System Fan Failure
If a fan fails, you will need to have it replaced with the same type. Contact your
vendor or Supermicro for information on replacement fans.
6-4 Drive Bay Installation/Removal
Removing the Front Bezel
If your system has a front bezel (optional) attached to the chassis, you must fi rst
remove it to gain access to the drive bays. To remove the bezel, fi rst unlock the
front of the chassis then press the release knob (see Figure 6-3). Carefully re-
move the bezel with both hands. A fi lter located within the bezel can be removed
for replacement/cleaning. It is recommended that you keep a maintenance log of
fi lter cleaning/replacement, since its condition will affect the airfl ow throughout the
whole system.
Figure 6-3. Removing the Front Bezel
1. Unlock
2. Press release knob
3. Remove bezel assembly