Datasheet
6-8
SUPERSERVER 7047R-3RF4+ User's Manual
Installing Components in the 5.25" Drive Bays
The 7047R-3RF4+ has two 5.25" drive bays. DVD-ROM drives can be installed
into these 5.25" drive bays.
1. First power down the system and then remove the top/left chassis cover to
access the drive components.
2. With the cover off, remove the two or four screws that secure the drive carrier
to the chassis (one side only) then push the entire empty drive carrier out
from the back.
Adding a DVD-ROM Drive
1. Remove the guide plates (one on each side) from the empty drive carrier and
screw them into both sides of the DVD-ROM drive using the holes provided.
2. Slide the DVD-ROM into the bay and secure it to the chassis with the drive
carrier screws you fi rst removed.
3. Attach the power and data cables to the drive.
4. Replace the top/left chassis cover before restoring power to the system.
Storage Module
If the 7047R-3RF4+ is to be used in a rack confi guration, you must turn the storage
module 90 degrees. This can be done before, during, or after setup.
Rotating the Storage Module
1. Open the chassis cover.
2. Disconnect any cables from the storage module to any components in the
chassis.
3. Push the storage module release lever to unlock the storage module.
4. Grasp the external edges of the storage module and pull it from the chassis.
5. Turn the storage module 90 degrees (as illustrated).
6. Reinsert the module into the chassis and reconnect the cords.