User's Manual (1.0b)

Chapter 1: Overview
1-9
System
Health
System Health/CPU Monitoring
Monitoring
• Onboard voltage monitoring for 1.2V +3.3V, 3.3V
standby, +5V, +5V standby, +12V, CPU core, mem-
ory, chipset, BMC, PCH, and battery voltages
• CPU/system overheat LED and control
• CPU Thermal Trip support
• Status monitor for speed control
• Status monitor for on/off control
• CPU Thermal Design Power (TDP) support of up to
145W (See Note 1 below.)
Fan Control
• Fan status monitoring via IPMI connections
• Dual cooling zone
• Low-noise fan speed control
• Pulse Width Modulation (PWM) fan control
System
Management
• PECI (Platform Environment Control Interface) 2.0
support
• UID (Unit Identication)/Remote UID
• System resource alert via SuperDoctor® 5
• SuperDoctor® 5, Watch Dog, NMI
• Chassis intrusion header and detection
Dimensions
• 12.00" (L) x 13.00" (W) (304.80 mm x 330.20 mm)
Note 1: The CPU maximum thermal design power (TDP) is subject to
chassis and heatsink cooling restrictions. For proper thermal management,
please check the chassis and heatsink specications for proper CPU TDP
sizing.
Note 2: For IPMI conguration instructions, please refer to the Embedded
IPMI Conguration User's Guide available at http://www.supermicro.com/
support/manuals/.
Note 3: It is strongly recommended that you change BMC log-in informa-
tion upon initial system power-on. The manufacture default username is
ADMIN and the password is ADMIN. For proper BMC conguration, please
refer to http://www.supermicro.com/products/info/les/IPMI/Best_Practices_
BMC_Security.pdf