User's Manual (1.0b)

2-26
X10QBi Platform User's Manual
X10QBi
Rev:1.02
MAC CODE
BAR CODE
MAC CODE
Power Button
Red (OH/Fan Fail/
PWR FaiL)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3V
3.3V
Blue Led Cathode
(UID)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Active LED
NIC1 Active LED
Power Button
The Power Button connection is located
on pins 1 and 2 of JF1. Momentarily
contacting both pins will power on/off
the system. This button can also be con-
gured to function as a suspend button
(with a setting in BIOS - see Chapter 5).
To turn off the power when the system is
set to suspend mode, press the button
for at least 4 seconds. Refer to the table
on the right for pin denitions.
Power Button
Pin Denitions (JF1)
Pin# Denition
1 Signal
2 Ground
Reset Button
The Reset Button connection is located
on pins 3 and 4 of JF1. Attach it to a
hardware reset switch on the computer
case. Refer to the table on the right for
pin denitions.
Reset Button
Pin Denitions (JF1)
Pin# Denition
3 Reset
4 Ground
A. Reset Button
B. PWR Button
A