Datasheet

4-20
X7DBi+ User's Manual
Hardware Monitor Logic (*See the Note on Page 4-19.)
CPU Temperature Threshold
This option displays a CPU temperature threshold that will activate the alarm system
when the CPU temperature reaches this pre-set temperature threshold. The options
are 75
o
C, 80
o
C, 85
o
C and 90
o
C.
Highlight this and hit <Enter> to see monitor data for the following items:
CPU1 Temperature/CPU1 Second Core/CPU2 Temperature/CPU2 Second
Core
PECI Agent 1 Temperature/PECI Agent 2 Temperature
PECI Agent 3 Temperature/PECI Agent 4 Temperature
System Temperature
Fan1-Fan8 Speeds: If the feature of Auto Fan Control is enabled, the BIOS will
automatically display the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vice versa.
If the option is set to 3-pin fan, the fan speed is controlled by voltage. If the option
is set to 4-pin, the fan speed will be controlled by Pulse Width Modulation (PWM).
Select 3-pin if your chassis came with 3-pin fan headers. Select 4-pin if your chas-
sis came with 4-pin fan headers. Select Workstation if your system is used as a
Workstation. Select Server if your system is used as a Server. Select Disable to
disable the fan speed control function and allow the onboard fans to constantly
run at full speed (12V). The Options are: 1. Disable, 2. 3-pin (Server), 3. 3-pin
(Workstation), 4. 4-pin (Server), and 5. 4-pin (Workstation),
Voltage Monitoring
The following items will be monitored and displayed:
P12V_VR0/P12V_VR1/FSB VTT/PXH Vcore/ES2B Vcore/CPU1Vcore/CPU2Vcore/
P3V3
Note: In the Windows OS environment, the Supero Doctor III settings take
precedence over the BIOS settings. When fi rst installed, Supero Doctor III adopts
the temperature threshold settings previously set in the BIOS. Any subsequent
changes to these thresholds must be made within Supero Doctor, since the SD
III settings override the BIOS settings. For the Windows OS to adopt the BIOS
temperature threshold settings, please change the SDIII settings to be the same
as those set in the BIOS.