User's Manual (1.0c)

2-28
X9SRi/X9SRE Motherboard Series User’s Manual
JLAN2
3
JSTBY
JCOM1
R625
MH7
MH1
MH5
41
FAN1
41
FAN2
4
1
FAN3
41
FAN4
41
FANA
JVR6
3
JVR5
1
3
JVR4
1
3
JVR3
1
3
JPB1
1
3
JPG1
1
JPL1
1
JPL2
JVR1
1
3
JVR2
1 3
JWD1
1
3
JPUSB1
1
JPME_RCV1
3
JPBIOS_RCV1
1
3
DP3
A
C
JI2C1
JI2C2
1
JOH1
1
JCF1
JL1
3-SGPIO2
1
2
7
8
3-SGPIO1
1
2
7
8
T-SGPIO1
2
7
8
T-SGPIO2
1
2
7
8
DIMM_C1
JUSB2
4
PCIX1
PCIX2
PCIX3
JPW1
1
12
24
JBT1
JPI2C1
1
5
SP1
+
PCIE6
PCIE5
PCIE4
X_BT1
JPW2
UID_LED
A
C
UID_SW
1
2
JTPM1
1
2
19
20
SAS4
SAS5 SAS6
SAS7 I-SATA2I-SATA3
I-SATA4
I-SATA5
JKBMS1
+
U8
JWF1
1
3
JTAG1
JD1
1
7
JF1
1
2
19
20
JVGA
JIPMB1
I-SATA1
I-SATA0
MAC CODE
MAC CODE
REV:1.01
Tested to Comply
With FCC Standards
FOR HOME OR OFFICE USE
DESIGNED IN USA
SAS CODE
JCOM2
1
5
6
9
JUSB45
2
7
10
JUSB67
1
2
7
JUSB89
1
2
7
10
JRK1
Pin3:PCH_DYN_SKU
Pin2:Ground
OFF:NORMAL
ON:ME IN FORCE UPDATA MODE
I-Button Header 1
Pin1:RAID_KEY_PCH
OFF:NORMAL
ON:RECOVER BIOS
UID
TPM/PORT80
JIPMB1
P1-DIMM4A
P1-DIMM4B
P1-DIMM3A
P1-DIMM3B
P1-DIMM2A
P1-DIMM2B
P1-DIMM1B
P1-DIMM1A
I-SATA5
I-SATA4
I-SATA3 I-SATA2
I-SATA1
I-SATA0
2-3 ENable
Power
Flash
KB/MOUSE
X9SRi
JPUSB1:USB Wake Up
1-2 Disable
PWRI2C
JF1
RST
ON
PWR
PWR
FF
FAIL
HDD
NIC
1
2
NIC
OH
LED
NMI
PWR
X
PWR LED
SPEAKER
1-3:
4-7:
JD1:
2-3:NMI
JWD1:Watch Dog
1-2:RST
LAN1
LAN2
JPL1/2: LAN
2-3 Disable
1-2 Enable
FAN4
VGA
COM1
USB0/1
INTRUSION
CHASSIS
OFF: SLAVE
ON: MASTER
JCF1:Compact Flash
Compact
SAS1/SAS3
SAS0/SAS2
3-SGPIO23-SGPIO1
Connect to IPMI
USB2
USB8/9
USB4/5
USB6/7
2-3 Disable
JPB: BMC
1-2 Enable
JSTBY : Wake on Lan
COM2
1-2 Enable
2-3 Disable
JPG1: VGA
OFF:DISABLE
ON: ENABLE
I2C Bus for PCI slot
JI2C1/JI2C2
SLOT4 PCI-E 3.0 X8 (IN X16)
SLOT5 PCI-E 2.0 X4 (IN X16)
SLOT6 PCI-E 3.0 X16
SLOT3 PCI-X 133/100MHZ
SLOT1 PCI-X 133/100MHZ
SLOT2 PCI-X 133/100MHZ
CLOSE 1st
OPEN 1st
JPW2
Unit ID Switch (UID SW)
The rear UID switch, the rear UID LED and
front UID LED on JF1 are designed to work
together. When the user pushes the rear
UID switch, the blue backpanel UID LED
and front UID LED will turn on. Push the
rear UID switch again to turn off UID LED
and the front UID LED. This provides easy
identication of a system unit that may be
in need of service.
UID Switch
Pin# Denition
1 Button In
2 Ground
3 Ground
4 Ground
A. UID Switch
B. Overheat/Fan Fail LED
B
A
Overheat/Fan Fail LED (JOH1)
The JOH1 header is used to connect an
LED to provide warnings of chassis over-
heat. This LED will also blink to indicate a
fan failure. Refer to the table on right for
pin denitions.
Overheat LED
Pin Denitions
Pin# Denition
1 P3V3
2 OH Active
OH/Fan Fail LED
Pin Denitions
State Message
Solid Overheat
Blinking Fan Fail